Infrastructure Requirements
12
01/2019-v1.0en
Every networked fitness console requires a dedicated Ethernet connection directly
from the facility’s network switches, based on Cat 6 (recommended) or Cat 5e
twisted-pair cable and eight-contact modular connectors.
NOTE
WOODWAY advises that a wired Ethernet connection is always best.
Alternatively, the ProSmart console can connect wirelessly to your facility’s network.
WOODWAY strongly advises against wirelessly connected devices. If the SiliconDust
TV Option was purchased, all treadmills must be connected to a wired network.
Consult with a wireless network specialist or your IT administrator for information
on installing and managing a wireless network.
4.2
Power Circuit Requirements
IMPORTANT!
The power cord must be properly protected at all times, both when in use and stor-
age.
Below are the standard electrical requirements by region. There are different op-
tions depending on which model you own. If you have a different electrical configu-
ration, please contact your sales representative.
DO NOT BEND OR REMOVE PRONGS!
The plugs are polarized, meaning the prongs are different sizes and the plug can
only fit in the outlet one way; if the plug does not fit, reverse the plug. If other
power cord plugs are required, please contact your sales representative.
Before connecting the treadmill to the power supply, the information on main volt-
age and frequency (found on the name plate) is to be compared with the on-site
connection values. Only connect the device if the values match. Power surges or
voltage drops can cause malfunctions or defects in the device.
No other treadmills or devices may be operated on the same supply line. Each
treadmill must be operated with its own circuit breaker. The treadmill must be
grounded.
DANGER
Danger of Death by Electric Shock!
Improper handling of electrical equipment by unqualified persons can cause
fatal electrical shock.
►
If necessary, allow only qualified personnel to perform electrical installa-
tion.
►
The power cord must not come into contact with hot surfaces or sharp
edges.
►
Electrical parts (e.g. motor, power cord, and power switch) must not come
in contact with water.
Data Networking
Requirements