Installation

Aggregate electrical ratings of the unit are expressed in kilowatts in this manual�

Single Phase Units:
Supplied with an appropriately rated plug and lead fi tted and be indicated as:

•  10A plug & lead fi tted

Some procedures in this manual require the power to the equipment to be turned 

off  and isolated. Turn the power OFF at the power point and unplug the power 

supply lead by the plug body.  If the power point is not readily accessible turn the 

equipment off  at the isolation switch or the circuit breaker in the switchboard.  

Attach a yellow “CAUTION-DO NOT OPERATE” tag. This must be performed 

where relevant unless the procedures specify otherwise.

FAILURE TO DO SO MAY RESULT IN ELECTRIC SHOCK.

WARNING

WARNING

This unit must be installed in accordance with AS/NZS 60335.1

Notes:

•  If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualifi ed persons in order to avoid a 

hazard� Please contact Stoddart for parts and we will advise how to do this in order to avoid any electrical hazard

•  The power cable should be dry and/or isolated from moisture or water

Electrical Connection

Information

Содержание W.CFSQ23

Страница 1: ...se care and maintenance of your quality Woodson product Models W CFSQ23 W CFSQ24 Cold Food Displays Self Serve SPECIFICATION INSTALLATION AND OPERATION MANUAL READ ALL INSTRUCTIONS BEFORE USE Revision...

Страница 2: ...Page Intentionally Left Blank Page 1 Due to continuous product research and development the information contained herein is subject to change without notice www stoddart com au www stoddart co nz...

Страница 3: ...osal Electrical Connection 6 Information Refrigeration Connections 7 Pre Installation Pressure Test TX Valves Refrigerant Plumbing Connections 7 Information Specification Climate Classes 8 Information...

Страница 4: ...our Woodson product according to these instructions your Woodson product should give you many years of reliable service Stoddart is a wholly Australian owned company which manufactures and distributes...

Страница 5: ...or near this unit Keep fingers out of pinch point areas Unit is not waterproof DO NOT use jet sprays hoses or pour water over on the exterior of the unit Only use this unit with voltage specified on...

Страница 6: ...vides access for future maintenance Place the unit on a level stable work surface capable of supporting its weight Do not position the unit in wet areas near heat and or steam sources near flammable s...

Страница 7: ...plug body If the power point is not readily accessible turn the equipment o at the isolation switch or the circuit breaker in the switchboard Attach a yellow CAUTION DO NOT OPERATE tag This must be p...

Страница 8: ...d to the refrigeration lines If the pressure tag is lost the preset pressure of the lines when leaving the factory should be 1380kPa 200psi Contact the manufacturer to confirm Any pressure loss MUST b...

Страница 9: ...Refrigerated Units in Commercial Kitchens would normally be climate class 4 CLIMATE CLASSES Test Room Climate Class Dry bulb temperature C Relative humidity Dew point C Water weightin dry air g kg 0 2...

Страница 10: ...com au www stoddart co nz Technical Specifications W CFSQ23 Specification 1168 TOP VIEW FRONT VIEW SIDE VIEW 607 1143 410 295 310 460 270 602 60 SPECIFICATIONS Width 1168mm Depth 607mm Height 1143mm V...

Страница 11: ...www stoddart com au www stoddart co nz W CFSQ24 Specification 1502 TOP VIEW FRONT VIEW SIDE VIEW 607 1143 410 295 310 460 270 602 60 SPECIFICATIONS Width 1502mm Depth 607mm Height 1143mm Voltage Frequ...

Страница 12: ...Let the unit cool then clean the whole unit including the shelves before placing in product Operation Unit is designed to run for a service period of approximately 3 4hrs this may vary depending on t...

Страница 13: ...the room temperature display KEY COMBINATIONS 1 Push and immediately release the SET key the display will show the Set point value 2 Push and immediately release the SET key or wait 5 seconds to disp...

Страница 14: ...ial cleaning agent that contains citric oxalic nitric phosphoric acid Do NOT use cleaning agents with chlorides or other harsh chemicals as this can cause corrosion After treatment wash with warm not...

Страница 15: ...th clean warm water until all soil has been removed 6 Using a clean sanitised cloth thoroughly wipe the stainless steel and metal parts dry Do NOT let water pool on the unit Check crevices and folds N...

Страница 16: ...ust fan Warm items in unit O Remove items Pre chill Air not circulating O Remove some items Clear air vents Grills Too many items in the unit overloaded O Remove some items Evaporator coil fins blocke...

Страница 17: ...Page Intentionally Left Blank Page 16 Due to continuous product research and development the information contained herein is subject to change without notice www stoddart com au www stoddart co nz...

Страница 18: ...Page 17 Due to continuous product research and development the information contained herein is subject to change without notice www stoddart com au www stoddart co nz...

Страница 19: ...Page 18 Due to continuous product research and development the information contained herein is subject to change without notice www stoddart com au www stoddart co nz...

Страница 20: ...Zealand Business Number 6837694 New Zealand Sales Tel 0800 79 1954 Email sales stoddart co nz Service Spare Parts Tel 0800 935 714 Email service stoddart co nz Email spares stoddart co nz www stoddar...

Отзывы: