Due to continuous product research and development,

the information contained herein is subject to change without notice.

www.stoddart.com.au

www.stoddart.co.nz

•  Threaded fasteners can loosen in service� Regular inspection and tightening should be carried out as required
•  Cleaning is recommended for health and safety purposes and to prolong the life of the unit
•  Do NOT use abrasive pads or cleaners on the stainless steel or any other metal parts of the unit
•  Do NOT use industrial chemical cleaners, caustic based cleaners or bleaches and bleaching agents, many will damage the metals and 

plastics used on this unit

•  When drying, metal surfaces should be wiped with a soft cloth in the same direction as grained polish
•  Do NOT remove any screws for cleaning� All internal sections of the unit are to be cleaned by a qualifi ed technician
•  This unit is NOT waterproof, do NOT hose, do NOT pour water directly onto the unit, do NOT immerse in water

•  Stainless steel exhibits good resistance to corrosion however, if not properly maintained stainless steel can rust and/or corrode
•  Any sign of mild rust and/or corrosion should be thoroughly cleaned with warm soapy water and dried as soon as possible
•  NEVER use abrasive pads or cleaners for cleaning
•  All metal surfaces should be checked while cleaning for damage, scuffs or scrapes as these can lead to rust and further damage to the 

product

•  Mild rust and/or corrosion can be treated with a commercial cleaning agent that contains citric/oxalic/nitric/phosphoric acid� Do NOT 

use cleaning agents with chlorides or other harsh chemicals as this can cause corrosion� After treatment, wash with warm (not hot) 
soapy water and dry thoroughly

•  Thoroughly wipe the surfaces dry after cleaning and do NOT let water pool on the unit� Check crevices and folds for pooling
•  When using, ensure all liquids and moisture is cleaned up straight away� Food liquids such as juices from vegetables and fruits should 

NOT be left on preparation surfaces

•  Do NOT leave items on the stainless steel such as cutting boards, rubber mats and bottles

•  To protect the polish, stainless steel should be dried by wiping a dry soft cloth in the same direction as grained polish
•  For NON-food contact surfaces, a light oil can be wiped on the surfaces with a cloth to enhance the stainless steel surface� Wipe in the 

direction of the grain

•  Some commercial stainless steel cleaners can leave residue or fi lm on the metal; this may trap fi ne particles of food on the surface, 

thus deeming the surfaces not food safe

IMPORTANT

WARNING

IMPORTANT

CAUTION

Threaded fasteners can loosen in service. 

Regular inspection and tightening should 

be carried out as required  

This unit is NOT waterproof, do NOT 

hose. DO NOT pour water directly onto 

the unit. DO NOT immerse in water

Some commercial stainless steel 

cleaners leave residue or fi lm on the 

metal that may entrap fi ne particles of 

food, deeming the surface not 

FOOD SAFE.

This unit includes refrigeration 

components. 

Cold surfaces can burn DO NOT touch 

these surfaces 

Cleaning

General Information

Corrosion Protection

Surface Finish

Operation

Содержание W.CFSQ23

Страница 1: ...se care and maintenance of your quality Woodson product Models W CFSQ23 W CFSQ24 Cold Food Displays Self Serve SPECIFICATION INSTALLATION AND OPERATION MANUAL READ ALL INSTRUCTIONS BEFORE USE Revision...

Страница 2: ...Page Intentionally Left Blank Page 1 Due to continuous product research and development the information contained herein is subject to change without notice www stoddart com au www stoddart co nz...

Страница 3: ...osal Electrical Connection 6 Information Refrigeration Connections 7 Pre Installation Pressure Test TX Valves Refrigerant Plumbing Connections 7 Information Specification Climate Classes 8 Information...

Страница 4: ...our Woodson product according to these instructions your Woodson product should give you many years of reliable service Stoddart is a wholly Australian owned company which manufactures and distributes...

Страница 5: ...or near this unit Keep fingers out of pinch point areas Unit is not waterproof DO NOT use jet sprays hoses or pour water over on the exterior of the unit Only use this unit with voltage specified on...

Страница 6: ...vides access for future maintenance Place the unit on a level stable work surface capable of supporting its weight Do not position the unit in wet areas near heat and or steam sources near flammable s...

Страница 7: ...plug body If the power point is not readily accessible turn the equipment o at the isolation switch or the circuit breaker in the switchboard Attach a yellow CAUTION DO NOT OPERATE tag This must be p...

Страница 8: ...d to the refrigeration lines If the pressure tag is lost the preset pressure of the lines when leaving the factory should be 1380kPa 200psi Contact the manufacturer to confirm Any pressure loss MUST b...

Страница 9: ...Refrigerated Units in Commercial Kitchens would normally be climate class 4 CLIMATE CLASSES Test Room Climate Class Dry bulb temperature C Relative humidity Dew point C Water weightin dry air g kg 0 2...

Страница 10: ...com au www stoddart co nz Technical Specifications W CFSQ23 Specification 1168 TOP VIEW FRONT VIEW SIDE VIEW 607 1143 410 295 310 460 270 602 60 SPECIFICATIONS Width 1168mm Depth 607mm Height 1143mm V...

Страница 11: ...www stoddart com au www stoddart co nz W CFSQ24 Specification 1502 TOP VIEW FRONT VIEW SIDE VIEW 607 1143 410 295 310 460 270 602 60 SPECIFICATIONS Width 1502mm Depth 607mm Height 1143mm Voltage Frequ...

Страница 12: ...Let the unit cool then clean the whole unit including the shelves before placing in product Operation Unit is designed to run for a service period of approximately 3 4hrs this may vary depending on t...

Страница 13: ...the room temperature display KEY COMBINATIONS 1 Push and immediately release the SET key the display will show the Set point value 2 Push and immediately release the SET key or wait 5 seconds to disp...

Страница 14: ...ial cleaning agent that contains citric oxalic nitric phosphoric acid Do NOT use cleaning agents with chlorides or other harsh chemicals as this can cause corrosion After treatment wash with warm not...

Страница 15: ...th clean warm water until all soil has been removed 6 Using a clean sanitised cloth thoroughly wipe the stainless steel and metal parts dry Do NOT let water pool on the unit Check crevices and folds N...

Страница 16: ...ust fan Warm items in unit O Remove items Pre chill Air not circulating O Remove some items Clear air vents Grills Too many items in the unit overloaded O Remove some items Evaporator coil fins blocke...

Страница 17: ...Page Intentionally Left Blank Page 16 Due to continuous product research and development the information contained herein is subject to change without notice www stoddart com au www stoddart co nz...

Страница 18: ...Page 17 Due to continuous product research and development the information contained herein is subject to change without notice www stoddart com au www stoddart co nz...

Страница 19: ...Page 18 Due to continuous product research and development the information contained herein is subject to change without notice www stoddart com au www stoddart co nz...

Страница 20: ...Zealand Business Number 6837694 New Zealand Sales Tel 0800 79 1954 Email sales stoddart co nz Service Spare Parts Tel 0800 935 714 Email service stoddart co nz Email spares stoddart co nz www stoddar...

Отзывы: