Trouble Shooting
25
MAN1248 (2/26/2018)
TROUBLE SHOOTING
Problem
Possible Cause
Solution
Oil Foam
Air getting in around pump shaft
seal
Replace seal.
Low on oil
Add oil to 5” on dip stick.
Air getting in around or through
suction hose fitting
Check and tighten fittings or if
necessary, put a clamp on hose.
Plugged suction hose screen
Check and clean - screen is in
tank.
Wrong kind of oil
Drain and fill with non-foaming oil.
Water in oil
Change oil and flush system
thoroughly and refill with clean oil.
Pump makes noise (other than
normal relief valve noise when oil
is going over the relief valve)
Oil too heavy
Drain and refill with proper oil.
Oil too cold
Allow to run at slow speed until
warm.
Pump not getting enough oil due to
restriction in suction line
Clean or replace suction line.
Pump not getting enough oil due to
collapsed suction hose
Replace hose.
Pump not getting enough oil due to
vacuum in reservoir
Remove cap and clean
Foreign matter in pump
Disassemble, clean and inspect
pump.