6
L100001
7
PLANING
FIREPLACE FRAMING
AND COVERING FACE
Firebox framing can be built before or after the appliance is set in place. Construct firebox framing following
Figure 2
and the
chart below for your specific installation requirements.
See Figure 3 on Page 8
for firebox dimensions. The framing headers may
rest on the top of the firebox standoff.
The firebox may be installed directly on a combustible floor or raised on a platform of an appropriate height. When the firebox
is installed directly on carpeting, tile, or other combustible material, other than wood flooring, the firebox shall be installed on a
metal or wood panel extending the full width and depth of the enclosure.
Figure 2 - Framing Dimensions
WARNING
IMPORTANT:
The following must be taken into consideration if
you decide to cover over the fireplace face:
1. The covering material must be non combustible, maximum 3/4" thick.
2. Minimum outside dimensions of the material over the facing are
60" x 34-1/2" (
see Figure 2
).
3. The inner opening in covering material must be minimum 49-1/4" wide, 14-1/4" tall and centered over the fireplace opening to
allow for or glass door removal. A 1/4" reveal must be provided all the way around the fireplace opening.
4. The cover should maintain an air gap of at least 1/8" between covering material and fireplace to allow for metal fireplace front
"
Do not fill spaces around firebox with insulation
or other materials. This could cause a fire.
INSIDE CHASE INSTALLATION
RECESSED INSTALLATION
MONTEREY
FRAMING DIMENSIONS
Note: These dimensions are for combustible framing
34.5"
6.5"
23.75"
23.75"
FOR COVERING FIREPLACE FACE
NON COMBUSTIBLE
NON COMBUSTIBLE
NON COMBUSTIBLE
60"
34.5"
13"
COMBUSTIBLE
COMBUSTIBLE
7"
60"
60"
60"
MINIMUM DIMENSIONS
49-1/4"
to expand and contract during operation.
5. PLEASE NOTE: Natural stone products may react to heat by discoloring or cracking. Woodbridge Fireplace Inc. is not
responsible
board must be used as a substrate.
"
for any damages due to covering materials used. If tiles are to be applied covering the fireplace face, a layer of cement