6
L100001
7
PRE-INSTALLATION INFORMATION
INSTALLING ABOVE 2000 FEET
•
In the USA, the appliance must be derated 4% for every 1,000 ft above 2,000 ft elevations
(at the factory).
•
In Canada, these appliances are certified for altitudes of 0 – 4,500 ft.
ORIFICE SIZES, PRESSURES AND BTUs
NATURAL GAS
PROPANE GAS
Manifold Press: (W.C.)
3.5"
Manifold Press: (W.C.)
10"
Maximum Supply Pressure
10.5"
Maximum Supply Pressure
13"
Minimum Supply Pressure
4.5"
Minimum Supply Pressure
11"
BEFORE YOU START
Read this homeowner
's
manual thoroughly and follow all instructions carefully. Inspect all contents for shipping damage and
immediately inform
the distributor
if any damage is found. Do not install any unit with damaged, incomplete, or substitute parts.
Check your packing list to verify that all listed parts have been received.
ITEMS REQUIRED FOR INSTALLATION
Tools:
Building Supplies:
• Phillips Screwdriver
• Framing Materials
• Hammer
• Wall Finishing Materials
• Saw and/or saber saw
• Caulking Material (Noncombustible)
• Level
• Fireplace Surround Material (Noncombustible)
• Measuring Tape
• Piping Complying with Local Codes
• Electric Drill and Bits
• Tee Joint
• Pliers
• Pipe Sealant Approved for use with Propane/LPG
• Square
(Resistant to Sulfur Compounds)
• Pipe Wrench
Model
Gas
Orifice Size
Input Rate, Btu/hr
Number
Type
As Shipped
Max
Min
Natural
#3
1
3
9
,000
2
7
,000
MONTEREY-
P
Propane
#
49
3
8
,000
2
7
,000
MONTEREY-N
Содержание MONTEREY-(N
Страница 31: ...LOG SET 31...
Страница 32: ...Figure 41 Log set placement LOG SETT contunue 32...
Страница 44: ...127 6...
Страница 45: ...127 6...
Страница 46: ...127 6...