CLEARANCES
CLEARANCES TO COMBUSTIBLES
MANTEL CLEARANCES
NOTE: The combustible area above the facing must not protrude more than
3
/
4
" from the facing. If it does, it is
considered a mantel and must meet the mantel requirements listed in this manual.
Follow these instructions carefully to ensure safe installation. Failure to follow instructions
exactly can create a fire hazard.
The appliance cannot be installed on a carpet, tile or other combustible material other
than wood flooring. If installed on carpet or vinyl flooring, the appliance shall be installed
on a metal, wood or noncombustible material panel extending full width and depth of
the appliance.
WARNING
The fireplace face m
ay
be
covered with
any non-
combustible ma
terial.
Allow clearance for
removal
of front air panel
and glass door.
6
6
6
6
6
6
6
6
14" min
48
" min
Minimum 7"
from both
side walls
12"
maximum
depth
COMBUSTIBLE MANTEL
to ceiling
Clearance to
Combustibles
0.75 1 1.25 1.5 1.75 2 2.25 2.5
2.5
2.25
2.0
1.75
1.5
1.25
1.0
0.75
*Minimum
7
inches from Side Wall to Fireplace opening
Figure 6 -
Side Clearance Chart
(
1
5
9
mm)
Top
6.25
"
To top standoff
0"
(0 mm)
Sides
1
"
(
26 mm)
To side standoffs
0"
(0 mm)
B
a
c
k
1
.
5
"
(38 mm)
To back standoffs
0"
(0 mm)
Floor
0"
(0 mm)
Front
36"
(915 mm)