DAILY OPERATION

OPERATION

FLAME HEIGHT

See “To Adjust Flame Height” box on previous page�

GREASE/DEBRIS TRAYS

Add water to the Grease/Debis Trays to catch drippings and simplify cleaning�

SPIT MOTOR

Press the orange ON/OFF button to turn the unit on and off� The button for the  
Spit Motor is located behind the left lower door (see photo to right)� 

DO NOT

 use water or any other liquid to cool down heated components of the Churrasco� Doing so could permanently damage the 

Grill and its components� Never spray water onto or around the burners� 

END OF DAY

CLEANING THE CABINET EXTERIOR

All exposed surfaces of the grill should be wiped clean daily using an approved mild cleaning solution� Stubborn residues may be 
removed using a non-metallic scouring pad� When scouring stainless steel, scrub with the grain to avoid scratching the finish� 

CLEANING THE CABINET INTERIOR

When adequately cool, lift and pull the Middle and Bottom Spit Rails to remove 
and clean� Spray then wipe the interior of the cabinet walls with oven cleaner, 
following the directions of the manufacturer� Wipe with wet cloth to remove 
streaks�
Lift, then tip down the Drop Down Burner Shield to clean the grease trough 
which runs behind the shield�

CLEANING THE ACCESSORIES

The Churrasco Spits should be cleaned using an approved mild detergent and hot water� 

CLEANING THE GREASE/DEBRIS TRAYS

Remove Grease/Debris Trays, being careful with the water in the trays� Remove the 
screen insert� Soak and scrub both sections using an approved mild detergent and hot 
water� Alternatively, these items can be cleaned in a dishwasher� For built-up debris, oven 
cleaner may be required�

EXHAUST HOOD

Refer to the exhaust hood manufacturer’s recommendations for inspection, maintenance and cleaning�

Narrow Grease/

Debris Tray with 

screen insert 

removed

Drop 

Down

Burner 

Shield

Skewer motor switch

Содержание CHURRASCO 900

Страница 1: ...ax 360 650 1166 www woodstone corp com WOOD STONE CORPORATION 1801 W Bakerview Rd Bellingham WA 98226 USA CHURRASCO 900 Specialty Grill Gas Fired Grill CHURRASCO WS LCHUG 900 DOC NO M0100 02 REVISED June 2015 Installation and Operation Manual ...

Страница 2: ...p com or visit woodstone corp com Wood Stone Corporation 1801 W Bakerview Rd Bellingham WA 98226 USA Toll Free 800 988 8103 Tel 360 650 1111 Fax 360 650 1166 TABLE OF CONTENTS TABLE OF CONTENTS CHURRASCO 3 CAUTIONS AND WARNINGS 4 SPECIFICATIONS 6 RECEIVING ASSEMBLY 7 CLEARANCES VENTING 8 UTILITY INFORMATION 9 LIGHTING INSTRUCTIONS 11 DAILY OPERATION 12 MAINTENANCE 13 TROUBLESHOOTING 14 WIRE DIAGRA...

Страница 3: ...no M0100 02 info woodstone corp com or visit woodstone corp com Wood Stone Corporation 1801 W Bakerview Rd Bellingham WA 98226 USA Toll Free 800 988 8103 Tel 360 650 1111 Fax 360 650 1166 INSTALLATION AND OPERATION MANUAL FOR THE WOOD STONE CHURRASCO GRILL SPECIALITY COOKING EQUIPMENT WS LCHUG 900 NG LP GAS FIRED CHURRASCO ADDITIONAL COPIES AVAILABLE UPON REQUEST CHURRASCO CASCADE ROTISSERIE ...

Страница 4: ...is oven be installed maintained and serviced by authorized professionals DO NOT USE PRODUCTS NOT SPECIFIED FOR USE WITH THIS OVEN WARNING Improper installation adjustment alteration service or maintenance can result in property damage injury or death Read the installation operation and maintenance instructions thoroughly before installing or servicing this equipment IMPORTANT Consult your local ga...

Страница 5: ...means of a connector for movable appliances There is a restraint on the appliance If disconnection of the restraint is necessary reconnect this restraint after the appliance has been returned to its originally installed position A MAJOR CAUSE OF FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES AIR SPACES TO COMBUSTIBLE MATERIALS IT IS OF THE UTMOST IMPORTANCE THAT THIS APPLIANCE BE INSTALLED ONLY ...

Страница 6: ...ing program of product improvement may require us to change specifications without notice woodstone net dfs CAD 0 Pn WS Top Level CSI Custom_Stainless_Industries Churasco LCHUG 900 LCHUG 900 WOODSTONE dft 1 of 1 71 4 190mm TYP 7 180mm 323 4 830mm 273 4 710mm 311 2 800mm 491 1250 351 2 900mm 373 4 960mm 61 4 160mm 231 2 600mm DATE PART ellingham WA 360 650 1111 www woodstone corp com WS LCHUG 9 Chu...

Страница 7: ...GRILL The crated grill can be moved using a forklift if space allows Alternatively a 1 000 lb pallet jack can be used Caster equiped models may be rolled into place over a level surface after removal from crate ASSEMBLY Install Spit Rails by placing pin into larger hole on either side and pushing down on rail Rail with 3 indentations goes in the middle position rail with 4 indentations goes on the...

Страница 8: ...of grill to non combustible construction is 36 to allow for combustion air Floor The unit is suitable for installation on combustible floors WARNING Do not pack required air spaces with insulation or other material Do not obstruct the flow of combustion and ventilation air VENTING The Wood Stone Circular Grill must be vented using a Listed Type 1 exhaust hood or one constructed in accordance with ...

Страница 9: ... Gas Fuel ANSI Z21 41 or CSA 6 9 ATTENTION INSTALLER EQUIPMENT RESTRAINT MUST BE PROVIDED Adequate means must be provided to limit the movement of the appliance without depending on the connector and the quick disconnect device or its associated piping to limit the appliance movement Use the eyehooks at the rear bottom of the unit to attach the restraining device s All utility connections to the g...

Страница 10: ...e fittings and pipe connections DO NOT USE A FLAME TO TEST FOR LEAKS Wood Stone recommends that a manual individual appliance shutoff valve be supplied located between the grill and the main gas supply and be left readily accessible MANIFOLD PRESSURE GAS RATING This appliance is equipped with a gas pressure regulator suitable for incoming pressure of up to 1 2 psi 14 W C If incoming pressure excee...

Страница 11: ...sed until visually confirming the pilot has lit through the Pilot View port then release the IGNITION button 3 Turn Pilot Knob to the ON position 1 Push and turn all Burner Control Knobs to OFF position The Low setting position OFF HIGH LOW PILOT position OFF position Red Ignition button ON position To adjust flame height depress Burner Control knob turn to the flame height desired then release Th...

Страница 12: ...ped clean daily using an approved mild cleaning solution Stubborn residues may be removed using a non metallic scouring pad When scouring stainless steel scrub with the grain to avoid scratching the finish CLEANING THE CABINET INTERIOR When adequately cool lift and pull the Middle and Bottom Spit Rails to remove and clean Spray then wipe the interior of the cabinet walls with oven cleaner followin...

Страница 13: ...gham WA 98226 USA Toll Free 800 988 8103 Tel 360 650 1111 Fax 360 650 1166 MAINTENANCE WEEKLY MAINTENANCE 1 With grill cool clean the Grill Burner Radiants Wipe away any debris 2 Clean fallen debris from the lower Grease Debris Trays 7 Grill Burner rRdiants 1 Verify Gas Control knob is in OFF position 2 Unscrew the Ignitor button to access the AA battery 3 Replace battery placing negative end into...

Страница 14: ... Clear injector Low gas pressure Increase pressure at main or grill regulator Blocked injector Clear injector Low gas pressure Increase pressure at main or grill regulator Cracked burner head Replace burner Manual shut off valve partially closed Open valve fully Pilot flame too small Raise pilot flame adjust at gas valve Low gas pressure Increase pressure at main or appliance regulator Clogged ori...

Страница 15: ... woodstone corp com Wood Stone Corporation 1801 W Bakerview Rd Bellingham WA 98226 USA Toll Free 800 988 8103 Tel 360 650 1111 Fax 360 650 1166 WIRE DIAGRAM CSI MOTOR SWITCH BOX WIRING DATE DIAG WD803 Rev 0 1 30 2014 Bellingham WA 1 360 650 1111 www woodstone corp com LINE GROUND NEUTRAL SWITCH BOX SWITCH LAMP GREY BLACK BLUE 4µF 220 VAC BLUE 120 VAC MOTOR SPECS Brother GL22N18X BMLC1A 1 Phase 1 5...

Страница 16: ...n wood fired equipment configurations in the event that pressed log products of any type have been burned in the equipment 9 In coal fired oven configurations in the event any type of coal other than anthracite coal fuel has been used 10 Damage resulting from the use of chemical cleaning products in the oven as well as any damage from liquids or chemicals including water being poured or sprayed in...