background image

Please contact Wood Stone at 1-800-988-8103 should service be necessary, or if you have any questions about 
your appliance. Our service hours are 8am to 4:30pm Pacific Standard Time. Follow the recorded instructions for 
Emergency Service if you require assistance during non-business hours. A Wood Stone technician will promptly 
respond to your call.

Zip tube will not 
stay lit

Thermocouple 
has good output 
but low reading 
at valve
Thermocouple 
has good output 
but inlet gas 
control magnet 
will not hold

Burners will not 
fully light 

Burners flash 
back 

• 

Loose, dirty or corroded terminals

 

Clean or tighten as required

• 

Grease under Flame Height knob  
prevents knob from being depressed

 

Remove knob and clean

• 

Pilot magnet defective

 

Replace auto gas valve

• 

Blocked burner ports

 

Clear burner ports

• 

Blocked cross-over

 

Clear burner cross-over

• 

Blocked injector

 

Clear injector

• 

Low gas pressure

 

Increase pressure at main or grill regulator

• 

Blocked injector

 

Clear injector

• 

Low gas pressure

 

Increase pressure at main or grill regulator

• 

Cracked burner head

 

Replace burner

• 

Manual shut-off valve partially closed

 

Open valve fully

• 

Pilot flame too small

 

Raise pilot flame, adjust at gas valve

• 

Low gas pressure

 

Increase pressure at main or appliance regulator

• 

Clogged orifice

 

Clean orifice

• 

Gas line too small

 

Replace gas line

• 

Flame blowing away from thermocouple

 

Eliminate drafts

• 

Defective thermocouple

 

Replace thermocouple

Loose, dirty or corroded terminals 

Clean or tighten as required�

PROBLEM

SOLUTION

POSSIBLE CAUSE

14

Churrasco–900 

Installation and Operation Manual

An ongoing program of product improvement may require us to change
specifications without notice. 

WS-LCHUG-900 Churrasco, 

Revised June 2015.                                    Doc no: M0100.02

[email protected]

 

or visit 

woodstone-corp.com

Wood Stone Corporation

1801 W. Bakerview Rd.
Bellingham, WA 98226  USA

Toll Free  800.988.8103
Tel  360.650.1111
Fax  360.650.1166

TROUBLESHOOTING

Содержание CHURRASCO 900

Страница 1: ...ax 360 650 1166 www woodstone corp com WOOD STONE CORPORATION 1801 W Bakerview Rd Bellingham WA 98226 USA CHURRASCO 900 Specialty Grill Gas Fired Grill CHURRASCO WS LCHUG 900 DOC NO M0100 02 REVISED June 2015 Installation and Operation Manual ...

Страница 2: ...p com or visit woodstone corp com Wood Stone Corporation 1801 W Bakerview Rd Bellingham WA 98226 USA Toll Free 800 988 8103 Tel 360 650 1111 Fax 360 650 1166 TABLE OF CONTENTS TABLE OF CONTENTS CHURRASCO 3 CAUTIONS AND WARNINGS 4 SPECIFICATIONS 6 RECEIVING ASSEMBLY 7 CLEARANCES VENTING 8 UTILITY INFORMATION 9 LIGHTING INSTRUCTIONS 11 DAILY OPERATION 12 MAINTENANCE 13 TROUBLESHOOTING 14 WIRE DIAGRA...

Страница 3: ...no M0100 02 info woodstone corp com or visit woodstone corp com Wood Stone Corporation 1801 W Bakerview Rd Bellingham WA 98226 USA Toll Free 800 988 8103 Tel 360 650 1111 Fax 360 650 1166 INSTALLATION AND OPERATION MANUAL FOR THE WOOD STONE CHURRASCO GRILL SPECIALITY COOKING EQUIPMENT WS LCHUG 900 NG LP GAS FIRED CHURRASCO ADDITIONAL COPIES AVAILABLE UPON REQUEST CHURRASCO CASCADE ROTISSERIE ...

Страница 4: ...is oven be installed maintained and serviced by authorized professionals DO NOT USE PRODUCTS NOT SPECIFIED FOR USE WITH THIS OVEN WARNING Improper installation adjustment alteration service or maintenance can result in property damage injury or death Read the installation operation and maintenance instructions thoroughly before installing or servicing this equipment IMPORTANT Consult your local ga...

Страница 5: ...means of a connector for movable appliances There is a restraint on the appliance If disconnection of the restraint is necessary reconnect this restraint after the appliance has been returned to its originally installed position A MAJOR CAUSE OF FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES AIR SPACES TO COMBUSTIBLE MATERIALS IT IS OF THE UTMOST IMPORTANCE THAT THIS APPLIANCE BE INSTALLED ONLY ...

Страница 6: ...ing program of product improvement may require us to change specifications without notice woodstone net dfs CAD 0 Pn WS Top Level CSI Custom_Stainless_Industries Churasco LCHUG 900 LCHUG 900 WOODSTONE dft 1 of 1 71 4 190mm TYP 7 180mm 323 4 830mm 273 4 710mm 311 2 800mm 491 1250 351 2 900mm 373 4 960mm 61 4 160mm 231 2 600mm DATE PART ellingham WA 360 650 1111 www woodstone corp com WS LCHUG 9 Chu...

Страница 7: ...GRILL The crated grill can be moved using a forklift if space allows Alternatively a 1 000 lb pallet jack can be used Caster equiped models may be rolled into place over a level surface after removal from crate ASSEMBLY Install Spit Rails by placing pin into larger hole on either side and pushing down on rail Rail with 3 indentations goes in the middle position rail with 4 indentations goes on the...

Страница 8: ...of grill to non combustible construction is 36 to allow for combustion air Floor The unit is suitable for installation on combustible floors WARNING Do not pack required air spaces with insulation or other material Do not obstruct the flow of combustion and ventilation air VENTING The Wood Stone Circular Grill must be vented using a Listed Type 1 exhaust hood or one constructed in accordance with ...

Страница 9: ... Gas Fuel ANSI Z21 41 or CSA 6 9 ATTENTION INSTALLER EQUIPMENT RESTRAINT MUST BE PROVIDED Adequate means must be provided to limit the movement of the appliance without depending on the connector and the quick disconnect device or its associated piping to limit the appliance movement Use the eyehooks at the rear bottom of the unit to attach the restraining device s All utility connections to the g...

Страница 10: ...e fittings and pipe connections DO NOT USE A FLAME TO TEST FOR LEAKS Wood Stone recommends that a manual individual appliance shutoff valve be supplied located between the grill and the main gas supply and be left readily accessible MANIFOLD PRESSURE GAS RATING This appliance is equipped with a gas pressure regulator suitable for incoming pressure of up to 1 2 psi 14 W C If incoming pressure excee...

Страница 11: ...sed until visually confirming the pilot has lit through the Pilot View port then release the IGNITION button 3 Turn Pilot Knob to the ON position 1 Push and turn all Burner Control Knobs to OFF position The Low setting position OFF HIGH LOW PILOT position OFF position Red Ignition button ON position To adjust flame height depress Burner Control knob turn to the flame height desired then release Th...

Страница 12: ...ped clean daily using an approved mild cleaning solution Stubborn residues may be removed using a non metallic scouring pad When scouring stainless steel scrub with the grain to avoid scratching the finish CLEANING THE CABINET INTERIOR When adequately cool lift and pull the Middle and Bottom Spit Rails to remove and clean Spray then wipe the interior of the cabinet walls with oven cleaner followin...

Страница 13: ...gham WA 98226 USA Toll Free 800 988 8103 Tel 360 650 1111 Fax 360 650 1166 MAINTENANCE WEEKLY MAINTENANCE 1 With grill cool clean the Grill Burner Radiants Wipe away any debris 2 Clean fallen debris from the lower Grease Debris Trays 7 Grill Burner rRdiants 1 Verify Gas Control knob is in OFF position 2 Unscrew the Ignitor button to access the AA battery 3 Replace battery placing negative end into...

Страница 14: ... Clear injector Low gas pressure Increase pressure at main or grill regulator Blocked injector Clear injector Low gas pressure Increase pressure at main or grill regulator Cracked burner head Replace burner Manual shut off valve partially closed Open valve fully Pilot flame too small Raise pilot flame adjust at gas valve Low gas pressure Increase pressure at main or appliance regulator Clogged ori...

Страница 15: ... woodstone corp com Wood Stone Corporation 1801 W Bakerview Rd Bellingham WA 98226 USA Toll Free 800 988 8103 Tel 360 650 1111 Fax 360 650 1166 WIRE DIAGRAM CSI MOTOR SWITCH BOX WIRING DATE DIAG WD803 Rev 0 1 30 2014 Bellingham WA 1 360 650 1111 www woodstone corp com LINE GROUND NEUTRAL SWITCH BOX SWITCH LAMP GREY BLACK BLUE 4µF 220 VAC BLUE 120 VAC MOTOR SPECS Brother GL22N18X BMLC1A 1 Phase 1 5...

Страница 16: ...n wood fired equipment configurations in the event that pressed log products of any type have been burned in the equipment 9 In coal fired oven configurations in the event any type of coal other than anthracite coal fuel has been used 10 Damage resulting from the use of chemical cleaning products in the oven as well as any damage from liquids or chemicals including water being poured or sprayed in...

Отзывы: