10
Installation and Operation Manual
An ongoing program of product improvement may require us to change
specifications without notice.
WS-LCHUG-900 Churrasco,
Revised June 2015. Doc no: M0100.02
or visit
woodstone-corp.com
Wood Stone Corporation
1801 W. Bakerview Rd.
Bellingham, WA 98226 USA
Toll Free 800.988.8103
Tel 360.650.1111
Fax 360.650.1166
3/4" NPT gas inlet connection
The Churrasco is equipped with a 3/4" NPT gas inlet connection� Have a licensed gas installer provide the hook-up and test all
fittings and pipe connections for leaks� Use approved gas leak detectors (soap solutions or equivalent) over and around the fittings
and pipe connections�
DO NOT USE A FLAME TO TEST FOR LEAKS!
Wood Stone recommends that a manual, individual appliance shutoff valve be supplied, located between the grill and the main gas
supply, and be left readily accessible�
MANIFOLD PRESSURE / GAS RATING
This appliance is equipped with a gas pressure regulator suitable for incoming pressure of up to 1/2 psi (14" W�C�)�
If incoming pressure exceeds 1/2 psi (14" W�C�), a suitable regulator, by others, must be installed�
Manifold pressure can be checked at the tap provided, which is located just beyond the outlet side of the regulator�
MANIFOLD PRESSURE / GAS RATING
WS-CHUG-900
Natural Gas (NG): 4.0" W.C.
98,000 BTU/hr
Propane (LG): 10.0" W.C.
87,000 BTU/hr
ELECTRICAL
120 VAC �33 A, 60 Hz� Cord, originating under unit, with NEMA 5-15 plug and 10' cord� Supply a grounded 3-prong receptacle�
DO NOT CUT OR REMOVE THE GROUNDING PRONG FROM THE PLUG.