Simple Set PID Settings
8
8-4
WMdoc122320
3.
Release the Manual
button, then release the UP
button.
The Simple Set control panel will display the Speed setting.
See Figure 8-3.
4.
Press the Auto
button several times until PGain, DGain and IGain settings appear.
5.
Use the Up
/Down
buttons to set the settings to the required values.
IMPORTANT!
The PID settings are factory-set and they should not be
changed. If necessary, set the PID settings to the following values:
PGain 1.0, DGain 0.0 and IGain 0.0.
6.
Press the Manual
button to return to the main menu.
FIG. 8-3
3H1128
Scroll Up/Down
Display
Manual
Auto