Assembly
Pump Installation
Assembly
CBNdoc080917
2-4
2
See Figure 2-2.
3.
Plug the pump into the top cord on the converter box. Plug the converter into a grounded
receptacle.
4.
Oil is pumped from the oil pan through the oil flow control valve to the grind area.
IMPORTANT! Be sure the rubber stop is properly installed before filling the oil pan.
Fill the pan with #165-CE oil to 1” (2.5 cm) from the top. Add oil as necessary to keep the
level at 1” from the top pan.
FIG. 2-2
SH0031B
Magnets
Pump Plate