SETWORKS OPERATION
Blade Distance Memory Buttons (A, B, C, D, E)
4
4-5
EGdoc031621
SETWORKS OPERATION
Using the scale, set the maximum distance between the blades (e.g. 250mm (9.842")).
Press and hold
Measure the distance between the blades and make sure the measured distance is the same as
read on the scale. If not,
for scale alignment instructions.
Enter the blade distance without any pauses. Confirm by pressing
.
4.3
Blade Distance Memory Buttons (A, B, C, D, E)
After turning on, the TBS-01 inscription appears on the display, and the Setworks is ready for operation
within a few seconds or after pressing
.
To set any blade distance, enter this value using the keypad and press
. The blades will
automatically move to the preset distance.
You can also change the blade distance manually using
.
You can store up to 5 blade distance values using the memory buttons.
To store any blade distance value using one of the memory buttons, press and hold
. ”ABC”
will appear on the upper display. Press any memory button (A, B, C, D or E), enter the desired
blade distance value and confirm by pressing
. Perform the same procedure for other
memory buttons. Press
to exit this function.