![Wood-mizer Accuset LT70 Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/wood-mizer/accuset-lt70/accuset-lt70_safety-operation-maintenance-and-parts-manual_994536031.webp)
Accuset Troubleshooting
Common Problems
Accuset Troubleshooting
60AS-R02doc032519
2-2
2
be caused by bad transducer cable connections. Check the cable connections.
At the transducer, check if the cables are plugged properly. Tighten the cable connections
if necessary.
If the cable connections are tight and the problem remains, inspect the transducer cables
for damage. Replace the transducer cables if necessary.
Perform the Accuset reset, if the transducer cable connections are okay and plugged
properly.
See Section 2.2.2 Resetting the Accuset
for instructions. If the display still
shows two horizontal lines after resetting the Accuset, call Customer Service for assis-
tance.
With Accuset in Manual Mode and activating the up/down drum switch...
4
Accuset does not make saw head move up and down.
Check the red control lights
located at the rear of Accuset and power box control panels (
), to determine the cause for this problem.
5
Saw head does not move up but moves down.
Check the upper row of lights at the
back of Accuset and power box control panels.
See Section 2.3 Up/Down Control Lights
for instructions.
If the lights are okay, reset the Accuset (
See Section 2.2.2 Resetting the Accuset
). If the
saw head still does not move up, call Customer Service for assistance.
6
Saw head does not move down but moves up.
Check the lower row of lights at the
back of Accuset and power box control panels.
See Section 2.3 Up/Down Control Lights
for instructions.
If the lights work properly, reset the Accuset (
See Section 2.2.2 Resetting the Accuset
). If
the saw head still does not move down, call Customer Service for assistance.
7
Accuset displays illegible characters.
First reset the display by turning the keyswitch
off (#0) and back on again.
See Section 1.1.5 Other Settings
of the Accuset operator’s
manual to check the language option. Change the language as needed. If the language is
not a cause of the problem, reset the Accuset to Factory Settings (
). If the display continues to show the problem, call Customer Ser-
vice for assistance.
8
Accuset display reads X/12 dimensions (Rev. A.00 - A.03 only).
When this problems
occurs, turn the key switch to the off (#0) position. Turn the key switch to the on (#1) or