![Wood-mizer Accuset LT70 Скачать руководство пользователя страница 41](http://html1.mh-extra.com/html/wood-mizer/accuset-lt70/accuset-lt70_safety-operation-maintenance-and-parts-manual_994536041.webp)
Accuset Troubleshooting
Up/Down Control Lights
Accuset Troubleshooting
60AS-R02doc032519
2-12
2
Use an Ohm meter to check the resistance between the MOSFET terminals.
IMPORTANT!
Set the meter to ohms (
), place the
red
meter lead in the “V-
” position and the
black
meter lead in
the “comm” position. Be sure to use the color meter leads
as specified below. Do not touch the meter leads during
testing to avoid false readings. Depending on your meter
type, infinite resistance may be indicated by displaying “OL”
or a very high value indicated in mega-ohms.
5.
Place the
red
meter lead to the MTRR terminal and
black
meter lead to GND. The meter
should indicate infinite resistance.
6.
Place the
red
meter lead to the MTRL terminal and the
black
meter lead to GND. The
meter should indicate infinite resistance.
7.
Place the
red
meter lead to the 12VDC terminal and
black
meter lead to MTRR. The
meter should indicate infinite resistance.
8.
Place the
red
meter lead to the 12VDC terminal and
black
meter lead to MTRL. The
meter should indicate infinite resistance.
9.
Place the
red
meter lead to the GND terminal and the
black
meter lead to one of the alu-
minum blocks on the panel. The meter should indicate infinite resistance.
10.
Place the
red
meter lead to the MTRR terminal and the
black
meter lead to one of the
aluminum blocks on the panel. The meter should indicate infinite resistance.
11.
Place the
red
meter lead to the MTRL terminal and the
black
meter lead to one of the
aluminum blocks on the panel. The meter should indicate infinite resistance.
12.
Place the
red
meter lead to the 12VDC terminal and the
black
meter lead to each of the
four connector pins, one pin at a time. The meter should indicate infinite resistance.
13.
Place the
black
meter lead to the GND terminal and the
red
meter lead to each of the
four connector pins, one pin at a time. The meter should indicate 10k
at pins 3 & 4 and
infinite resistance at pins 1 & 2. (Pin 1 is indicated by the extruded notch on the connector
housing).
Содержание Accuset LT70
Страница 21: ...Setup Operation Control Setup Setup Operation 60AS R02doc032519 1 18 1 ...
Страница 43: ...Accuset Troubleshooting Up Down Control Lights Accuset Troubleshooting 60AS R02doc032519 2 14 2 ...
Страница 48: ...Replacement Parts Sensor Assembly 3 3 3 60AS R02doc032519 Replacement Parts ...