![Wood-mizer Accuset LT70 Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/wood-mizer/accuset-lt70/accuset-lt70_safety-operation-maintenance-and-parts-manual_994536020.webp)
Setup & Operation
Control Setup
1
1-17
60AS-R02doc032519
Setup & Operation
Kp
(Proportional Gain) - This value is a multiplier that determines the speed that
Accuset moves the saw head to the setting increment.
NOTE:
The factory default
setting for Kp is “1” and will work for super sawmills. Adjust the value to “3” for stan-
dard sawmills. After adjustment the Kp value will probably never need to be
changed. Increasing the Kp value will allow Accuset to move the saw head faster
but may also cause the control to drastically overshoot the desired setting.
To adjust the Kp setting, press the Kp button then use the Up or Down buttons to
raise or lower the value.
After making the desired PID Value adjustments, go to the desired Accuset mode. Test
how the changes affect Accuset performance. If the new settings improve performance,
push the Manual button to change to Manual Mode and push the Up button for Configura-
tion Menu 1. Press the Save Settings button. If the new settings cause undesirable
results, turn the key switch to the off (#0) position to return the PID Values to the previ-
ously stored settings.
Analog Limits.
These settings are used for troubleshooting diagnostics and should not
be adjusted by the operator unless directed to do so by a qualified Wood-Mizer service
representative.
1.1.6 Restore Factory Defaults
Accuset Rev. E.04+:
To return all Accuset settings the their factory default values, press
and hold the Toggle button and turn the key switch on. Release the Toggle button and
press "Default".
Accuset Rev. E.00-E.03:
To reset the control to factory settings, push and hold the Tog-
gle button and turn the key switch on. Press “Yes” to reset the Accuset.
Accuset prior to Rev. E.00:
Pressing both the Up and Down arrow buttons simultane-
ously and turning the key switch on resets the control to factory settings.
The Accuset settings are now returned to their factory default values, including:
PID values.
Rev. B.00+ only:
The default values are set for DC-Powered model
sawmills.
to reconfigure for use with AC-powered model saw-
mills.
Calibration settings.
to recalibrate the Accuset control.
Rev. E.04+ Only:
Auto-bump feature off.
to turn Auto-bump on.
Содержание Accuset LT70
Страница 21: ...Setup Operation Control Setup Setup Operation 60AS R02doc032519 1 18 1 ...
Страница 43: ...Accuset Troubleshooting Up Down Control Lights Accuset Troubleshooting 60AS R02doc032519 2 14 2 ...
Страница 48: ...Replacement Parts Sensor Assembly 3 3 3 60AS R02doc032519 Replacement Parts ...