![Wood-mizer Accuset LT70 Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/wood-mizer/accuset-lt70/accuset-lt70_safety-operation-maintenance-and-parts-manual_994536023.webp)
Setup & Operaton
Mode Selection
Setup & Operaton
60AS-R02doc032519
1-20
1
head is being raised. The Increment Settings buttons work in the same manner as
described in Auto-Down Mode.
NOTE:
The sixteen increment settings apply to Auto-Down
AND Auto-Up modes. If you change a setting in Auto-Down
mode, it will also change when you are in Auto-Up mode.
Pattern Mode
- This mode
references the bed surface
and allows you to program up to
six different increments calculated up from the bed. The sixth (top) increment repeats
itself up to the upper limit of the saw head travel. The bottom increment indicates the size
of the remaining cant when the pattern is complete.
Reference Mode
- This mode allows the operator to program up to four pre-set locations
along the saw head travel. The factory default settings are at the bottom (3/4”), the loca-
tion where the saw head is calibrated (12”), a location midway between the calibration
and the top (24”), and the top (34 1/2”).