![Wood-mizer Accuset LT70 Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/wood-mizer/accuset-lt70/accuset-lt70_safety-operation-maintenance-and-parts-manual_994536037.webp)
Accuset Troubleshooting
Up/Down Control Lights
Accuset Troubleshooting
60AS-R02doc032519
2-8
2
2.3
Up/Down Control Lights
The up/down control lights are located on the back side of the Accuset front panel, next to
the power light and on the power control panel inside the power box. To access the con-
trol lights, remove the eight screws securing the Accuset front panel. Remove the control
panel from its original location without disconnecting the wires. For remote units, you also
need to check the control lights located on the power control panel inside the power box.
Turn the key switch to the on (#1) or accessory (#3) position to check the control lights for
operation.
The properly working control lights change while pushing the up/down drum switch
located on the right side of the sawmill control box. When the up/down drum switch is in
the neutral position, only the BR and BL lights should be on.
See Figure 2-3.
Only the BR and BL lights are on when the up/down drum switch is not in
use.
If the Accuset works properly and the up/down drum switch is pushed forward to move
the saw head up, only the UP, TL, and BR lights come on.
If the Accuset works okay and the up/down drum switch is pushed down to move the saw
head down, only the DN, TR, and BL lights come on.
See below to determine the cause for your problem.
FIG. 2-3
SM0284-4
UP
DN
TL
TR
BR
BL
DETAIL
See DETAIL
Содержание Accuset LT70
Страница 21: ...Setup Operation Control Setup Setup Operation 60AS R02doc032519 1 18 1 ...
Страница 43: ...Accuset Troubleshooting Up Down Control Lights Accuset Troubleshooting 60AS R02doc032519 2 14 2 ...
Страница 48: ...Replacement Parts Sensor Assembly 3 3 3 60AS R02doc032519 Replacement Parts ...