Component Access
Drawer Microwave
(Models MWD24-2 / MWD30-2)
4-13
#813632 - Revision B - December, 2009
Rack Gear Removal:
1.
Follow the Drawer Microwave disassembly as previ-
ously stated on page 4-6.
2.
Open the drawer and keep it open.
3.
To discharge the high voltage capacitor, wait for 60
seconds.
4.
Remove the drawer microwave by following steps 1,
2, 5, 8, 9 & 10 as instructed under "Drawer Assembly
and Choke Removal”.
5.
Remove the three (3) mounting screws holding the
rack gear to the bottom slide rail (See Figure 4-17).
7.
Proceed in reverse to reinstall the new rack gear.
Figure 4-17. Rack Gear Removal
Screws
(Third screw
not shown)
Major Control Components:
1.
Drawer Microwave must be removed from its installation. Remove the top plate, both side cabinet panels, the
exhaust duct and the back plate.
2.
Only attempt to remove a major control component after allowing the capacitor to self discharge which takes
approximately 60 seconds, or discharge capacitor as instructed on page 4-3.
3.
All major control components are attached with phillips head screws. To Remove a component, extract its
mounting screws after detaching electrical wiring.
NOTE:
Be careful to maintain proper wire location. Check for clear wire marking before removing any wires and
label any wires that can not be easily identified.
Drawer Microwave Major Control Components
HV
Capacitor
HV Trans-
former
Thermal
Cut-Out
Magnetron
Fan Motor
Power
Supply
Monitor
Fuse
Bottom
view of unit
Bottom
Drawer
Support
Rack
Gear
Содержание MWD24-2
Страница 2: ......
Страница 34: ...Drawer Microwave Models MWD24 2 MWD30 2 Theory of Operation 3 22 813632 Revision B December 2009 ...
Страница 48: ...Drawer Microwave Models MWD24 2 MWD30 2 Component Removal 4 14 813632 Revision B December 2009 ...
Страница 64: ...Drawer Microwave Models MWD24 2 MWD30 2 Troubleshooting Guide 5 16 813632 Revision B December 2009 ...
Страница 71: ......
Страница 72: ......