Drawer Microwave
(Models MWD24-2 / MWD30-2)
Theory of Operation
3-20
#813632 - Revision B - December, 2009
Pin No.
47
48-52
53
54
55
56
57
P05
P04-P00
P57
P56
TXD1
RXD1
P53
OUT
OUT
OUT
IN
IN
IN
IN
Magnetron High-Voltage Circuit Driving Signal:
To turn on and off cook relay
(RY2), in 100% power operation, the signals holds “H” level during microwave cook-
ing and “L” level while not cooking. In other cooking modes (90%, 80%, 70%, 60%,
50%, 40%, 30%, 20%, 10%, 0%) the signal turns to “H” level and “L” level in repeti-
tion according to power level.
Used for initial balancing of the bridge circuit (absolute humidity sensor).
Common Relay Driving Signal
(Square Waveform : 60Hz):
To turn
on and off the shut-off relays (RY1).
The square waveform voltage is deliv-
ered to the relay (RY1) driving circuit.
Terminal not used.
Terminal not used.
Terminal not used.
Terminal not used.
Signal
I/O
Description
Microwave Cooking Mode
Other Cooking Mode
Vari Mode
On Time
Off Time
On Time Off Time
100% power
32 sec.
0 sec.
60 sec.
0 sec.
90% power
30 sec.
2 sec.
54 sec.
6 sec.
80% power
26 sec.
6 sec.
48 sec.
12 sec.
70% power
24 sec.
8 sec.
42 sec.
18 sec.
60% power
22 sec.
10 sec.
36 sec.
24 sec.
50% power
18 sec.
14 sec.
30 sec.
30 sec.
40% power
16 sec.
16 sec.
24 sec.
36 sec.
30% power
12 sec.
20 sec.
18 sec.
42 sec.
20% power
8 sec.
24 sec.
12 sec.
48 sec.
10% power
6 sec.
26 sec.
4 sec.
56 sec.
0% power
0 sec.
32 sec.
0 sec.
60 sec.
During cooking
L: GND
H: +5V
16.7 msec.
Содержание MWD24-2
Страница 2: ......
Страница 34: ...Drawer Microwave Models MWD24 2 MWD30 2 Theory of Operation 3 22 813632 Revision B December 2009 ...
Страница 48: ...Drawer Microwave Models MWD24 2 MWD30 2 Component Removal 4 14 813632 Revision B December 2009 ...
Страница 64: ...Drawer Microwave Models MWD24 2 MWD30 2 Troubleshooting Guide 5 16 813632 Revision B December 2009 ...
Страница 71: ......
Страница 72: ......