54
F E A T U R E S
Natural
or LP gas models
Fits
standard 610 mm deep cabinets with zero
clearance for easy installation
Optional
infrared charbroiler, infrared griddle
and French Top configurations
Classic
stainless steel exterior finish
Dual
brass burners with automatic reignition at
all settings, .1 kW simmer to 4.7 kW high
Porcelain-coated
cast iron top grates
Large
red control knobs with four position
settings and chrome bezels—optional black
knobs available
Stainless
steel drip tray on ball bearing slides
P L A N N I N G I N F O R M A T I O N
Wolf gas rangetops come in 914 mm and 1219
mm widths. Specifications on the following
pages provide overall dimensions, finished rough
opening dimensions and installation specifics for
each size of gas rangetop. We have minimized
the information contained in the illustrations,
concentrating on the critical information you
need to plan your installation.
IMPORTANT NOTE:
Caution must be used in
planning the proper installation of the Wolf gas
rangetop to avoid fires or damage to adjacent
cabinetry or kitchen equipment. Follow the
minimum clearances established in the finished
rough opening dimensions. Refer to specifica-
tions on the following pages for your model.
E L E C T R I C A L
|
G A S R E Q U I R E M E N T S
Specifications on the following pages provide
electrical and gas requirements for each size
of gas rangetop.
International (I) models come with a factory
installed transformer and require a 220-240
V AC, 50/60 Hz electrical supply, fused at the
correct rating for the unit. The appropriate elec-
trical connection must be provided in accordance
with local requirements. The service should have
its own 15 amp circuit breaker.
IMPORTANT NOTE:
A ground fault circuit
interrupter (GFCI) is not recommended and may
cause interruption of operation.
Wolf gas rangetops are designed to operate on
natural gas at 12.5 mb WC (water column)
pressure or LP (propane) gas at 25 mb WC
pressure. The minimum line pressure for natural
gas is 17.5 mb WC and 27.4 mb WC for LP gas.
The maximum gas supply pressure to the regula-
tor should never exceed 34.9 mb WC; 3.5 kPa.
Wolf recommends the use of a 13 mm I.D.
commercial-type flex hose; this is the minimum
size that may be used. All plumbing to the flex
hose
must
be 19 mm minimum I.D. pipe.
IMPORTANT NOTE:
A separate external gas
shut-off valve must be located near the range
in an accessible location.
The platform for the rangetop must be 19 mm
thick and include a cut-out at the right rear for
gas supply and electrical connections.
Locate electrical and gas supply within the
shaded area shown in the Installation Specifica-
tions illustration for your model.
You must follow all local codes and ordinances
when installing your services.
B U R N E R R A T I N G
Gas Rangetops
Surface Burners
4.7 kW with .1 kW
delivered at simmer
Infrared Charbroiler
4.7 kW
Infrared Griddle
5.3 kW
French Top
4.4 kW
Refer to the specific model requirements
for risers in non-island installations.
W O L F G A S R A N G E T O P S