63
W O L F C O O K T O P V E N T I L A T I O N
I N S T A L L A T I O N
Refer to installation
instructions shipped
with each Wolf
product for detailed
specifications.
Specifications on the following pages provide
overall dimensions, blower and ducting consider-
ations, and installation specifics for downdraft
ventilation systems. Also refer to the cooktop
ventilation recommendations on pages 68–69.
If a Model DD30 is installed in combination with
two integrated modules, an integrated module
support for downdraft ventilation is required.
Contact your Wolf dealer for information on
accessory components.
P L A N N I N G I N F O R M A T I O N
Wolf downdraft ventilation systems are available
in 762 mm, 914 mm and 1143 mm widths. The
downdraft should be at least as wide as the
cooking surface.
Downdraft Model DD30 will fit most 762 mm
wide cabinets, Model DD36 will fit most 914 mm
wide cabinets and Model DD45 will fit most
1156 mm wide cabinets. It is recommended that
oversized cabinets be used for easier installation.
Cabinet backs may need to be removed.
IMPORTANT NOTE:
To install a downdraft
system and a Wolf cooktop, you must allow for
a minimum 638 mm flat counter space from
front to back. A countertop with a raised lip
and/or backsplash may not allow enough space
for proper installation. 60 mm of flat countertop
is required behind the cooktop and 44 mm is
necessary between the back edge of the
cooktop and inside of cabinet back.
IMPORTANT NOTE:
This appliance must be
used with a Wolf-approved control module and
top cover.
The remote-mounted control module is available
as a sales accessory for Models DD30 and DD36
and is included with Model DD45. Installation of
the control module must be within 3 m of the
downdraft assembly and a minimum of 102 mm
from the outer edge of cooktop element or
burner. You will be required to drill three holes
and connect the downdraft to the control
module with the provided wire.
O V E R A L L D I M E N S I O N S
Downdraft Systems
Models DD30I / DD30R
60 mm
762 mm
230 mm
667 mm
38 mm
DEPTH OF
DOWNDRAFT CHIMNEY
Models DD36I / DD36R
914 mm
819 mm
60 mm
230 mm
38 mm
DEPTH OF
DOWNDRAFT CHIMNEY
1156 mm
1048 mm
60 mm
230 mm
38 mm
DEPTH OF
DOWNDRAFT CHIMNEY
Models DD45I / DD45R