background image

63

W O L F C O O K T O P V E N T I L A T I O N

I N S T A L L A T I O N

Refer to installation
instructions shipped
with each Wolf
product for detailed
specifications.

Specifications on the following pages provide

overall dimensions, blower and ducting consider-

ations, and installation specifics for downdraft

ventilation systems. Also refer to the cooktop

ventilation recommendations on pages 68–69.

If a Model DD30 is installed in combination with

two integrated modules, an integrated module

support for downdraft ventilation is required.

Contact your Wolf dealer for information on

accessory components.

P L A N N I N G I N F O R M A T I O N

Wolf downdraft ventilation systems are available

in 762 mm, 914 mm and 1143 mm widths. The

downdraft should be at least as wide as the

cooking surface.

Downdraft Model DD30 will fit most 762 mm

wide cabinets, Model DD36 will fit most 914 mm

wide cabinets and Model DD45 will fit most

1156 mm wide cabinets. It is recommended that

oversized cabinets be used for easier installation.

Cabinet backs may need to be removed.

IMPORTANT NOTE:

To install a downdraft

system and a Wolf cooktop, you must allow for

a minimum 638 mm flat counter space from

front to back. A countertop with a raised lip

and/or backsplash may not allow enough space

for proper installation. 60 mm of flat countertop

is required behind the cooktop and 44 mm is

necessary between the back edge of the

cooktop and inside of cabinet back.

IMPORTANT NOTE:

This appliance must be

used with a Wolf-approved control module and

top cover.

The remote-mounted control module is available

as a sales accessory for Models DD30 and DD36

and is included with Model DD45. Installation of

the control module must be within 3 m of the

downdraft assembly and a minimum of 102 mm

from the outer edge of cooktop element or

burner. You will be required to drill three holes

and connect the downdraft to the control

module with the provided wire.

O V E R A L L D I M E N S I O N S

Downdraft Systems

Models DD30I / DD30R

60 mm

762 mm

230 mm

667 mm

38 mm

DEPTH OF

DOWNDRAFT CHIMNEY

Models DD36I / DD36R

914 mm

819 mm

60 mm

230 mm

38 mm

DEPTH OF

DOWNDRAFT CHIMNEY

1156 mm

1048 mm

60 mm

230 mm

38 mm

DEPTH OF

DOWNDRAFT CHIMNEY

Models DD45I / DD45R

Содержание CT15I/S

Страница 1: ...INTERNATIONAL DESIGN GUIDE ...

Страница 2: ...cifications I M P O R T A N T N O T E As you follow these instructions you will notice warning and caution symbols This blocked information is important for the safe and efficient installation of Wolf equipment There are two types of potential hazards that may occur during installation Another footnote we would like to identify is IMPORTANT NOTE This highlights information that is especially relev...

Страница 3: ...f the ten different cooking modes your client chooses In addition our dual stacked burners on the gas cooktops dual fuel ranges and sealed burner rangetops are all sealed and offer you the capa bility of simmering foods Our electric cooktops are unique to the industry with their capabilities of providing simmer on all elements and the melt feature on one of the elements The triple element on the 9...

Страница 4: ...ket Exhaust vent Location of rating plate Oven door light switch Thermostat Three removable racks L S E R I E S O V E N F E A T U R E S Model ISO30U S shown Model ISO30U S Model IDO30U S Model ISO36U S W O L F L S E R I E S B U I L T I N O V E N S It s hard to put into a few words the differences you will see in the Wolf L Series ovens compared to others on the market Some of those differ ences ar...

Страница 5: ...en may be installed below an electric or gas cooktop Wolf built in ovens are designed and agency approved for installation with Wolf cooktops only Refer to the electric and gas cooktops sections for additional specifications A built in oven cannot be installed below a Wolf rangetop E L E C T R I C A L R E Q U I R E M E N T S International I models come with a factory installed transformer and requ...

Страница 6: ...be installed next to another 762 mm single oven You must allow for a 64 mm space between the oven rough openings Also a separate inner wall is required for each oven between openings Refer to installation instructions shipped with each Wolf product for detailed specifications 6 B U I L T I N O V E N S 691 mm OPENING HEIGHT 724 mm OPENING WIDTH 127 mm 102 mm 610 mm min OPENING DEPTH E E E E 838 mm ...

Страница 7: ...cal Rating 5 1 kW at 240 V Total Amps 21 Shipping Weight 131 kg Undercounter Installation I N S T A L L A T I O N O P T I O N S The Wolf 914 mm single oven may be installed below a Wolf 914 mm electric or gas cooktop Unless you are using cabinets deeper than 610 mm it is recommended that the electrical supply be placed in the base cabinet to the right of the oven within reach of the conduit The 91...

Страница 8: ...er oven 127 L Overall Interior Dim 635 mm x 419 mm W x H x D x 483 mm each Usable Interior Dim 546 mm x 419 mm W x H x D x 416 mm each Cabinet Width 838 mm rec 762 mm min Cabinet Depth 610 mm min Min Base Support 181 kg Opening Width 724 mm Opening Height 1260 mm Trim Overlaps 5 mm top 3 mm bottom 19 mm each side Electrical Supply 220 240 V AC 50 60 Hz 50 amp dedicated circuit Conduit 1 5 m flexib...

Страница 9: ...with multiple temperature zones True Simmer setting on all elements Melt setting on one element Hot surface indicators on all elements High frequency pulsation elements improve cooking performance and control Temperature limiter to ensure that safe operating temperature of ceramic glass is never exceeded Child safety lock key and universal off W O L F E L E C T R I C C O O K T O P S F R A M E D E ...

Страница 10: ...to the countertop Refer to pages 57 66 for ventilation specifications E L E C T R I C A L R E Q U I R E M E N T S Electric cooktops require a separate grounded 220 240 V AC 50 60 Hz electrical supply with its own circuit breaker Locate electrical supply within the shaded area shown in the Installation Specifications illustration for your model IMPORTANT NOTE When an oven is installed below the coo...

Страница 11: ...I O N S Model ICT15E S I N S T A L L A T I O N S P E C I F I C A T I O N S Model ICT15E S Countertop Cut Out Dimensions W O L F E L E C T R I C C O O K T O P S S P E C I F I C A T I O N S 381 mm Framed Electric Cooktop Overall Width 381 mm Overall Height 89 mm Overall Depth 533 mm Heating Elements Two Temperature Zones Three Max Element Power 750 W 2200 W dual Max Element Power 1200 W single Cabin...

Страница 12: ... W and two dual 950 W 1900 W Max Element Power 1200 W and 1500 W two single Cabinet Width 838 mm rec 762 mm min Cabinet Depth 578 mm min Height Clearance 102 mm min Cut Out Width 721 mm Cut Out Depth 489 mm Electrical Supply 220 240 V AC 50 60 Hz 40 amp dedicated circuit Conduit 1 2 m flexible 3 wire Electrical Rating 6 8 kW at 240 V Shipping Weight 20 kg If the 762 mm cooktop is to be used with a...

Страница 13: ...00 W Max Element Power 750 W 2200 W dual Max Element Power 1200 W 1500 W three single and 1800 W Cabinet Width 991 mm rec 914 mm min Cabinet Depth 578 mm min Height Clearance 102 mm min Cut Out Width 873 mm Cut Out Depth 489 mm Electrical Supply 220 240 V AC 50 60 Hz 50 amp dedicated circuit Conduit 1 2 m flexible 3 wire Electrical Rating 9 4 kW at 240 V Shipping Weight 27 kg If the 914 mm cooktop...

Страница 14: ...ition on all settings Large 5 0 kW burner with 2 kW delivered at simmer Models ICBCT30G S and ICBCT36G S only Medium 4 0 kW burner with 2 kW delivered at simmer Small 3 2 kW burners with 1 kW delivered at simmer Electronic spark ignition system True Simmer setting on all burners Illuminated control panel with two tiered control knobs Low profile cast iron continuous burner grates with matte porcel...

Страница 15: ... ground fault circuit interrupter GFCI is not recommended and may cause interruption of operation Wolf gas cooktops are designed to operate on natural gas I2H I2E and I2E at 20 mb pressure or LP propane gas at 37 mb WC pressure They are supplied with an ISO 14 male gas connection at the right rear corner on the bottom of the cooktop The male connector exits the unit straight down Locate electrical...

Страница 16: ... COUNTERTOP 64 mm min 489 mm COOKTOP CUT OUT DEPTH 381 mm OVERALL WIDTH 533 mm OVERALL DEPTH 102 mm Countertop Cut Out Dimensions O V E R A L L D I M E N S I O N S 381 mm Gas Cooktop I N S T A L L A T I O N S P E C I F I C A T I O N S 381 mm Gas Cooktop S P E C I F I C A T I O N S 381 mm Gas Cooktop Overall Width 381 mm Overall Height 102 mm Overall Depth 533 mm Burner Rating 1 4 0 kW with 2 kW de...

Страница 17: ...A T I O N S P E C I F I C A T I O N S 762 mm Gas Cooktop S P E C I F I C A T I O N S 762 mm Gas Cooktop Overall Width 762 mm Overall Height 102 mm Overall Depth 533 mm Burner Rating 1 5 0 kW with 2 kW delivered at simmer 1 4 0 kW with 2 kW delivered at simmer 2 3 2 kW with 1 kW delivered at simmer Cabinet Width 838 mm rec 762 mm min Cabinet Depth 578 mm min Height Clearance 102 mm min Cut Out Widt...

Страница 18: ...Depth 533 mm Burner Rating 1 5 0 kW with 2 kW delivered at simmer 1 4 0 kW with 2 kW delivered at simmer 3 3 2 kW with 1 kW delivered at simmer Cabinet Width 991 mm rec 914 mm min Cabinet Depth 578 mm min Height Clearance 102 mm min Cut Out Width 889 mm Cut Out Depth 489 mm Electrical Supply 220 240 V AC 50 60 Hz 15 amp dedicated circuit Gas Rating 18 6 kW Shipping Weight 30 kg I N S T A L L A T I...

Страница 19: ...ple gas cooktops or modules are installed next to one another they can receive their gas supply from a common line However each unit must have its own regulator installed between the mainline and the cooktop or module W O L F I N T E G R A T E D M O D U L E S C O U N T E R T O P C U T O U T D I M E N S I O N S Installation of Multiple Cooktops or Modules I N T E G R A T E D M O D U L E S 381 mm Wi...

Страница 20: ...s surface is resistant to scratching staining impact and heat Induction elements heat cookware not the glass for a cooler and safer cooking surface Cookware sensing elements will not be energized without an iron or magnetic stainless steel pan on the cooktop surface Illuminated electronic touch controls with graduated control lighting High efficiency elements deliver power and control Hi Power mod...

Страница 21: ...pping Weight 14 kg If the induction cooktop is to be used with any combination of additional cooktop units or modules with a filler strip the cut out width increases to 356 mm IMPORTANT NOTE A minimum height clearance of 152 mm is required If a shelf is installed below the unit a 25 mm gap at the rear of the cabinet shelf is necessary to allow for proper ventilation Failure to do so could result i...

Страница 22: ...att individually controlled heating elements front and back for even grilling Illuminated electronic touch controls with graduated control lighting Low profile one piece cast iron grilling grate with matte porcelain finish Black porcelain coated grease deflection plates Easy to clean removable porcelain collection pan Independent digital timer CE certified E L E C T R I C G R I L L F E A T U R E S...

Страница 23: ...et Depth 578 mm min Height Clearance 159 mm min Cut Out Width 356 mm Cut Out Depth 489 mm Electrical Supply 220 240 V AC 50 60 Hz 15 amp dedicated circuit Electrical Rating 2 8 kW Shipping Weight 28 kg Unit dimensions may vary to 3 mm P L A N N I N G I N F O R M A T I O N The illustrations provide the overall dimensions and finished cut out dimensions that you need to plan for in your installation...

Страница 24: ...ckable stainless steel steamer insert pans one solid and one perforated Uses include steaming vegetables eggs and custard double boiling proofing bread dough warming food and melting chocolate Can function as a slow cooker for 8 10 hours Reversible domed glass lid for easy storage Independent digital timer Digital temperature readout and preheat indicator Electronic drain CE certified E L E C T R ...

Страница 25: ... L A N N I N G I N F O R M A T I O N The illustrations provide the overall dimensions and finished cut out dimensions that you need to plan for in your installation IMPORTANT NOTE When multiple cooktops or modules are installed side by side refer to page 19 for countertop cut out dimensions For the drain connection the 16 mm outlet from the valve will accept a drain hose that must flow downward to...

Страница 26: ...e and two small side by side each with wire basket hanger Low profile lid Melt feature for shortening or lard Independent digital timer Digital temperature readout and preheat indicator Easy manual locking drain capability Recommended for installation with any Wolf framed electric cooktop or the Wolf electric grill module CE certified E L E C T R I C F R Y E R F E A T U R E S Model ICBIF15 S W O L...

Страница 27: ...uit Electrical Rating 2 6 kW Shipping Weight 14 kg Unit dimensions may vary to 3 mm P L A N N I N G I N F O R M A T I O N The illustrations provide the overall dimensions and finished cut out dimensions that you need to plan for in your installation IMPORTANT NOTE When multiple cooktops or modules are installed side by side refer to page 19 for countertop cut out dimensions The electric fryer modu...

Страница 28: ...l and LP gas Stainless steel top construction with classic stainless steel finish High output 5 3 kW burner Automatic electronic reignition system Illuminated control panel Individual spark ignition system Two interchangeable cast iron burner grates with matte porcelain finish wok grate and low profile continuous grate Deep drawn burner pan G A S M U L T I F U N C T I O N C O O K T O P F E A T U R...

Страница 29: ...and any combustible surface directly below the cooktop Unit dimensions may vary to 3 mm P L A N N I N G I N F O R M A T I O N The illustrations provide the overall dimensions and finished cut out dimensions that you need to plan for in your installation IMPORTANT NOTE When multiple cooktops or modules are installed side by side refer to page 19 for countertop cut out dimensions This cooktop can ac...

Страница 30: ...tainers with lids that divide the drawer into sections keeping different dishes warm at the same time Electronic controls are hidden regardless of your panel selection Choose from the classic stain less steel look or the integrated drawer front which allows for a custom wood panel Wolf offers optional decorative handles for the inte grated drawer front Keep in mind there are significant changes to...

Страница 31: ...abinet is required for an overlay applica tion and 635 mm deep cabinet for a flush inset application Model ICBWWD30 with integrated drawer front can accommodate installations with a 762 mm or 914 mm cooktop It may also be installed in combination with a 762 mm single or double oven or a 914 mm single oven Dimensions will vary according to the specific installation Keep in mind that the width of th...

Страница 32: ...s steel drawer front for detailed specifica tions These instructions can also be found on our website wolfappliance com Dimensions will vary according to the specific installation 727 mm OPENING WIDTH E 127 mm 102 mm 838 mm RECOMMENDED CABINET WIDTH 762 mm min 914 mm STANDARD FLOOR TO COUNTER HEIGHT 127 mm min BOTTOM OF OPENING TO FLOOR 610 mm min CABINET DEPTH 232 mm OPENING HEIGHT 606 mm min OPE...

Страница 33: ... instructions can also be found on our website wolfappliance com 635 mm min CABINET DEPTH 749 mm OPENING WIDTH E 127 mm 102 mm 838 mm MINIMUM CABINET WIDTH 914 mm STANDARD FLOOR TO COUNTER HEIGHT 127 mm min BOTTOM OF OPENING TO FLOOR Allow enough room for placement of anti tip block 610 mm THICKNESS OF DRAWER FACE FOR OPENING DEPTH DIMENSION WILL VARY 260 mm OPENING HEIGHT 251 mm 51 mm x 51 mm ANT...

Страница 34: ... mm widths Combined with the top configuration options the different configurations you can choose from are numerous Model numbers indicate the top configurations C charbroiler G griddle and F French Top All Wolf dual fuel ranges come in the classic stainless steel finish The electric oven s feature the Wolf exclusive dual convection system that delivers even temperature and airflow throughout Its...

Страница 35: ... through your Wolf dealer W O L F D U A L F U E L R A N G E S D U A L F U E L R A N G E F E A T U R E S Model IDF484CG shown F E A T U R E S Natural or LP gas rangetop with dual convection electric oven s 457 mm oven on 1219 mm range is single convection Optional infrared charbroiler infrared griddle and French Top configurations Classic stainless steel exterior finish with island trim included Di...

Страница 36: ...r your model International I models come with a factory installed transformer and require a 220 240 V AC 50 60 Hz electrical supply fused at the correct rating for the unit The appropriate elec trical connection must be provided in accordance with local requirements Wolf dual fuel ranges are designed to operate on natural gas at 12 5 mb WC water column pressure or LP propane gas at 25 mb WC pressu...

Страница 37: ...ctions shipped with each Wolf product for detailed specifications 483 mm LOCATION OF ELECTRICAL 914 mm 937 mm TO COOKING SURFACE VENTILATION HOOD 457 mm min TO COUNTERTOP LOCATION OF GAS AND ELECTRICAL EXTENDS 76 mm ON FLOOR FROM BACK WALL 914 mm FINISHED ROUGH OPENING WIDTH 83 mm 216 mm 381 mm LOCATION OF GAS SUPPLY 762 mm min TO 914 mm max TO BOTTOM OF VENTILATION HOOD 914 mm min COUNTERTOP TO C...

Страница 38: ... Range O V E R A L L D I M E N S I O N S 1219 mm Dual Fuel Range S P E C I F I C A T I O N S 1219 mm Dual Fuel Range Overall Width 1216 mm Overall Height to cooking surface 937 mm Overall Depth 749 mm Large Oven Overall Interior Cap 127 L Overall Interior Dim 635 mm x 419 mm W x H x D x 483 mm Usable Interior Dim 546 mm x 419 mm W x H x D x 416 mm Small Oven Overall Interior Cap 71 L Overall Inter...

Страница 39: ... instructions shipped with each Wolf product for detailed specifications 330 mm LOCATION OF ELECTRICAL 914 mm 937 mm TO COOKING SURFACE VENTILATION HOOD LOCATION OF GAS AND ELECTRICAL EXTENDS 76 mm ON FLOOR FROM BACK WALL 83 mm 787 mm 254 mm LOCATION OF GAS SUPPLY 1530 mm FINISHED ROUGH OPENING WIDTH 457 mm min TO COUNTERTOP 762 mm min TO 914 mm max TO BOTTOM OF VENTILATION HOOD 914 mm min COUNTER...

Страница 40: ...ivers maximum heat transfer at higher settings the lower tier continuous flame ably handles the subtleties of simmering and melting Patented features along with the Wolf exclusive infrared charbroiler infrared griddle and French Top ensure this rangetop stands out from the rest in performance as well as beauty Wolf sealed burner rangetops come in 762 mm 914 mm and 1219 mm widths and are available ...

Страница 41: ...cast iron continuous top grates A C C E S S O R I E S Sealed Burner Rangetops 127 mm and 254 mm classic stainless steel risers 508 mm classic stainless steel riser with shelf Black control knobs one set available at no cost Chrome or brass bezels One piece wok grate and single burner grate Porcelain cast two burner S grate SRT Downdraft trim kit Model ICBSRT304 only Hardwood cutting board griddle ...

Страница 42: ...top The Wolf sealed burner rangetop is CB approved and manufactured for a 220 240 V AC 50 60 Hz electrical supply to operate the electronic ignition system The service should have its own 15 amp circuit breaker IMPORTANT NOTE A ground fault circuit interrupter GFCI is not recommended and may cause interruption of operation Wolf sealed burner rangetops are designed to operate without a regulator on...

Страница 43: ...14 mm max TO BOTTOM OF VENTILATION HOOD 762 mm min COUNTERTOP TO COMBUSTIBLE MATERIALS 19 mm PLATFORM TOP VIEW OF PLATFORM E G 406 mm 406 mm 102 mm BACK WALL ISLAND INSTALLATIONS 305 mm MINIMUM CLEARANCE FROM BACK OF RANGETOP TO COMBUSTIBLE REAR WALL ABOVE COUNTERTOP 0 mm TO NON COMBUSTIBLE MATERIALS LOCATION OF GAS AND ELECTRICAL SUPPLY CUT OUT WITHIN SHADED AREA THROUGH BOTTOM OF PLATFORM 914 mm...

Страница 44: ...SER 724 mm OVERALL DEPTH 216 mm OVERALL HEIGHT COOKING SURFACE 191 mm 235 mm I N S T A L L A T I O N S P E C I F I C A T I O N S 914 mm Sealed Burner Rangetop O V E R A L L D I M E N S I O N S 914 mm Sealed Burner Rangetop Unit dimensions may vary to 3 mm S P E C I F I C A T I O N S 914 mm Sealed Burner Rangetop Overall Width 911 mm Overall Height to cooking surface 216 mm Overall Depth 724 mm Ope...

Страница 45: ...KING SURFACE 191 mm 235 mm I N S T A L L A T I O N S P E C I F I C A T I O N S 1219 mm Sealed Burner Rangetop O V E R A L L D I M E N S I O N S 1219 mm Sealed Burner Rangetop Unit dimensions may vary to 3 mm S P E C I F I C A T I O N S 1219 mm Sealed Burner Rangetop Overall Width 1216 mm Overall Height to cooking surface 216 mm Overall Depth 724 mm Opening Width 1219 mm Opening Height 191 mm platf...

Страница 46: ...rations you can choose from are numerous Model numbers indicate the top configurations C charbroiler G griddle and F French Top Advanced standard features such as an infrared oven broiler convection baking and dual burners along with the Wolf exclusive infrared charbroiler infrared griddle and French Top are all yours for the asking The freedom to customize your gas range will make you and your cl...

Страница 47: ...tainless steel legs in front and rear casters Full side panels and skirt G A S R A N G E F E A T U R E S Model IR484CG shown with 127 mm riser 127 mm riser optional Dual brass burners Pull out drip tray Convection fan switch Oven indicator light Burner drip pan Oven light switch Porcelain coated cast iron top grates Infrared charbroiler optional Infrared griddle optional Oven light switch Full sid...

Страница 48: ... its own 15 amp circuit breaker IMPORTANT NOTE A ground fault circuit interrupter GFCI is not recommended and may cause interruption of operation Locate electrical and gas supply within the shaded area shown in the Installation Specifica tions illustration for your model Wolf gas ranges are designed to operate on natural gas at 12 5 mb WC water column pressure or LP propane gas at 25 mb WC pressur...

Страница 49: ...ct for detailed specifications 762 mm min COUNTERTOP TO COMBUSTIBLE MATERIALS 762 mm TO 914 mm COUNTERTOP TO BOTTOM OF VENTILATION HOOD VENTILATION HOOD 768 mm FINISHED ROUGH OPENING WIDTH ISLAND INSTALLATIONS 305 mm MINIMUM CLEARANCE FROM BACK OF RANGE TO COMBUSTIBLE REAR WALL ABOVE COUNTERTOP 0 mm TO NON COMBUSTIBLE MATERIALS G 127 mm 51 mm 305 mm E 305 mm 254 mm 140 mm 203 mm LOCATION OF GAS SU...

Страница 50: ...ISER 692 mm 235 mm 721 mm OVERALL DEPTH 1060 mm WITH 127 mm RISER I N S T A L L A T I O N S P E C I F I C A T I O N S 914 mm Gas Range O V E R A L L D I M E N S I O N S 914 mm Gas Range S P E C I F I C A T I O N S 914 mm Gas Range Overall Width 914 mm Overall Height to cooking surface 940 mm Overall Depth 721 mm Overall Oven Interior Capacity 156 L Overall Interior Dim 762 mm x 473 mm W x H x D x ...

Страница 51: ...hen installing a gas range with a charbroiler or griddle against a combustible surface 762 mm min COUNTERTOP TO COMBUSTIBLE MATERIALS 914 mm min FOR CHARBROILER 762 mm TO 914 mm COUNTERTOP TO BOTTOM OF VENTILATION HOOD VENTILATION HOOD LOCATION OF GAS SUPPLY EXTENDS 76 mm ON FLOOR FROM BACK WALL 1226 mm FINISHED ROUGH OPENING WIDTH 76 mm ISLAND INSTALLATIONS 305 mm MINIMUM CLEARANCE FROM BACK OF R...

Страница 52: ...T I O N S P E C I F I C A T I O N S 1524 mm Gas Range O V E R A L L D I M E N S I O N S 1524 mm Gas Range S P E C I F I C A T I O N S 1524 mm Gas Range Overall Width 1524 mm Overall Height to cooking surface 940 mm Overall Depth 721 mm Overall Oven Interior Capacity per oven 125 L Overall Interior Dim 610 mm x 473 mm W x H x D x 432 mm each Usable Interior Dim 610 mm x 419 mm W x H x D x 432 mm ea...

Страница 53: ... 914 mm and 1219 mm widths and are available in natural or LP gas with your choice of several top configura tions Model numbers indicate the top configura tions C charbroiler G griddle and F French Top This appliance is certified by Star K to meet strict religious regulations in conjunction with specific instructions found on www star k org Porcelain coated cast iron top grates Dual brass burners ...

Страница 54: ...ls come with a factory installed transformer and require a 220 240 V AC 50 60 Hz electrical supply fused at the correct rating for the unit The appropriate elec trical connection must be provided in accordance with local requirements The service should have its own 15 amp circuit breaker IMPORTANT NOTE A ground fault circuit interrupter GFCI is not recommended and may cause interruption of operati...

Страница 55: ...tions 356 mm 203 mm 921 mm FINISHED ROUGH OPENING WIDTH 19 mm PLATFORM TOP VIEW OF PLATFORM E G 203 mm 76 mm BACK WALL 13 mm 70 mm ISLAND INSTALLATIONS 305 mm MINIMUM CLEARANCE FROM BACK OF RANGETOP TO COMBUSTIBLE REAR WALL ABOVE COUNTERTOP 0 mm TO NON COMBUSTIBLE MATERIALS 19 mm PLATFORM 241 mm OPENING HEIGHT 610 mm 330 mm max 914 mm 457 mm min TO COUNTERTOP LOCATION OF GAS AND ELECTRICAL SUPPLY ...

Страница 56: ...BS 70 mm 267 mm OVERALL HEIGHT 241 mm 51 mm COOKING SURFACE I N S T A L L A T I O N S P E C I F I C A T I O N S 1219 mm Gas Rangetop O V E R A L L D I M E N S I O N S 1219 mm Gas Rangetop S P E C I F I C A T I O N S 1219 mm Gas Rangetop Overall Width 1219 mm Overall Height to cooking surface 267 mm Overall Depth 692 mm Opening Width 1226 mm Opening Height 241 mm platform to countertop Electrical S...

Страница 57: ... lines of the Wolf E Series cooktop hoods there s a lot of hard nosed functional thinking Brilliant halogen lighting illuminates your cooking surface Powerful multi speed blowers whisk away smoke and odors Wall mount hoods in three widths and island hood are available in classic stainless steel E Series cooktop wall and island hoods are recommended for use with Wolf electric and gas cooktops and i...

Страница 58: ...00 CFM internal blower IMPORTANT NOTE E Series cooktop wall and island hoods are recommended for use with Wolf electric and gas cooktops along with inte grated modules and should be at least as wide as the cooking surface Wolf E Series cooktop wall and island hoods come with a telescopic flue that allows you to reach a ceiling height of 2 4 m to 2 7 m with a finished look Specifications on the fol...

Страница 59: ...ischarge Vertical Internal Blower 500 CFM included with Model ICTEWH36I Blower Options Contact your Wolf dealer Electrical Supply 220 240 V AC 50 60 Hz 15 amp dedicated circuit Shipping Weight 21 kg shell only Blower options vary with the cooking surface Refer to the cooktop ventilation recommendations on pages 68 69 762 mm OVERALL WIDTH 450 mm OVERALL DEPTH 510 mm 80 mm 200 mm TO 620 mm 250 mm 27...

Страница 60: ...ht 790 mm including chimney Maximum Height 1210 mm full extension Overall Depth 450 mm Bottom of Hood to Countertop 650 mm to 760 mm Duct Size 150 mm Round Discharge Vertical Internal Blower 500 CFM included Electrical Supply 220 240 V AC 50 60 Hz 15 amp dedicated circuit Shipping Weight 26 kg shell only 1067 mm OVERALL WIDTH 550 mm OVERALL DEPTH 2 4 m TO 2 7 m FLOOR TO CEILING HEIGHT 650 mm TO 76...

Страница 61: ...the outside or using a sales acces sory charcoal filter in a non ducting installation internal blower I models only Wolf cooktop wall and island hoods have an 150 mm round vertical discharge Ducting can run through the roof external wall or eave Ducting through an eave requires an internal blower Refer to the illustrations below E Series cooktop wall and island hoods will operate most efficiently ...

Страница 62: ...an be used with sealed burner rangetop Model ICBSRT304 An accessory trim kit is necessary for this installation Contact your Wolf dealer for details C O N T R O L K I T O P T I O N S Downdraft Systems Model DD30I DD30R Classic DD30CONTROL S Model DD36I DD36R Classic DD36CONTROL S Control module and top cover have the stainless steel finish Control kits also include mounting brackets RJ45 connec to...

Страница 63: ...stallation Cabinet backs may need to be removed IMPORTANT NOTE To install a downdraft system and a Wolf cooktop you must allow for a minimum 638 mm flat counter space from front to back A countertop with a raised lip and or backsplash may not allow enough space for proper installation 60 mm of flat countertop is required behind the cooktop and 44 mm is necessary between the back edge of the cookto...

Страница 64: ...M Remote Electrical Supply 220 240 V AC 60 Hz 15 amp dedicated circuit Power Cord 8 m 3 prong Shipping Weight 34 kg S P E C I F I C A T I O N S Models DD36I DD36R Overall Width 914 mm Overall Height 230 mm above countertop Overall Depth 60 mm Duct Size DD36I 83 mm x 254 mm Duct Size DD36R 83 mm x 356 mm Discharge Adjustable Blower DD36I 500 CFM Internal Blower Options 1100 CFM In Line DD36R 900 12...

Страница 65: ...ms require a separate grounded 120 V AC 60 Hz power supply The service should have its own 15 amp circuit breaker and a grounded 3 prong recepta cle should be located within the reach of the 8 m power cord The specific location of the outlet is not critical as long as it is within reach of the power cord that is located midway top and bottom on the right side of the downdraft IMPORTANT NOTE If Mod...

Страница 66: ...etal ductwork For best performance 254 mm round ductwork is recommended The downdraft will operate most efficiently when ductwork does not exceed 12 m in length DISCHARGE CUT OUT DIMENSIONS 260 mm x 89 mm INTERNAL BLOWER 362 mm x 89 mm IN LINE OR REMOTE BLOWER CENTERLINE OF COUNTERTOP CUT OUT 416 mm INTERNAL BLOWER 546 mm IN LINE OR REMOTE BLOWER 140 mm INTERNAL BLOWER 108 mm IN LINE OR REMOTE BLO...

Страница 67: ...ndraft and connects to the blower More ducting is attached to the other side of the blower and runs to the exterior of the home An in line blower is a good option for those who do not want the blower mounted inside the downdraft but cannot or prefer not to mount a remote blower on the exterior of the home 457 mm 559 mm 632 mm 305 mm 457 mm 203 mm BLOWER 110IL I N L I N E B L O W E R Remote blowers...

Страница 68: ...DD30 DD36 DD45 Sealed Burner Rangetops Model ICBSRT304 600 Use these recommendations to determine total CFM when installing multiple cooktops or modules C F M Recommendations are based on total kW output Wolf recommends 1 CFM per 03 kW Additional CFM may be required for char broilers griddles and long duct runs D O W N D R A F T S C O O K T O P V E N T I L A T I O N C F M R E C O M M E N D A T I O...

Страница 69: ...O P T I O N S Blower Description Blower Number Downdraft Models 500 CFM Internal Included with I Models DD30I DD36I DD45I 1100 CFM In Line BLOWER 110IL 808332 DD30R DD36R DD45R 900 CFM Remote BLOWER 90REM 801641 DD30R DD36R DD45R 1200 CFM Remote BLOWER 120REM 801642 DD30R DD36R DD45R 1500 CFM Remote BLOWER 150REM 804701 DD30R DD36R DD45R Adjustable discharge 83 mm x 254 mm duct for internal blower...

Страница 70: ... Appliance Inc an affiliate of Sub Zero Inc Neither this book nor any information or images contained herein may be copied or used in whole or in part without the express written permission of Wolf Appliance Inc an affiliate of Sub Zero Inc Wolf Appliance Inc all rights reserved ...

Страница 71: ...71 ...

Страница 72: ...WOLF APPLIANCE INC PO BOX 44848 MADISON WI 53744 USA WOLFAPPLIANCE COM 8 1 0 2 9 5 8 2 0 0 7 ...

Отзывы: