- Fit the 3/4" pipe connectors for the heating flow on the l.h. side, for the heating return

on the r.h. side, using the flat gaskets and union nuts supplied. Wind hemp around
the 1/2" gas fitting in the centre of the boiler and fit the pipe connector.

- Push the straight maintenance valve together with the compression fitting onto the

l.h. pipe connector and tighten lightly.

- Push the straight maintenance valve together with the safety valve connection onto

the r.h. pipe connector and tighten lightly. Wind hemp around the safety valve
connection.

- Wind hemp around one side of the straight connector and insert into the gas ball valve.

Push the gas ball valve together with the compression fitting onto the centre pipe
connector and tighten lightly.

The parts may be moved for the further installation, if necessary. Tighten the
compression fittings after the installation has been completed.

- Wind hemp around one elbow of the SW connection set for installation on finshed

walls, and install in the primary flow, return and gas ball valve.

- Install the connection panel on the wall, centrally aligned with the boiler.

Note the height dimension of 785 mm.

- Route the on-site lines for flow, return, DHW, gas, safety blow-off and circulation (if

applicable) in accordance with the following diagram to the control panel. The pipes
must provide a female thread at their ends and reach the connection panel.

Left  hand  supply  lines

          Right hand supply lines

Please note: On-site lines must be routed, so that the CSW 120 / TSW 120

DHW cylinders can be located flush against the wall.

- Wind hemp around one side of the straight connector compression fitting, and secure

to the on-site lines on the connection panel.

- Wind hemp around all threaded connections on the DHW cylinder and install the

compression fitting I/O nipples.
Close the DHW cylinder connection with the cap supplied if no DHW circulation pipe
is to be installed.

- Push the CSW 120, TSW 120 DHW cylinder into the connection panel until it is flush

with the boiler, and level with the adjustable feet to dimension 790 mm.

- When using a pipe cover (accessory), adjust the gap between the gas fired boiler and

the TSW 120 DHW cylinder to 300 mm, using the adjustable cylinder feet.

Pipe connections

Connection panel installation

Straight connector on the connection panel

Elbow

Preparing the CSW 120, TSW 120
DHW cylinder

I nipples

Straight valve

(maintenance)

Straight valve

with safety valve

(maintenance)

Gas ball

valve

Straight
connector

On-site pipe with
female thread

Connection panel

Compression fitting -
straight connector

CSW / TSW connection set
for installation on finished walls

Connection set installation

Circulation

Circulation

Drain

Heating water
return

Drain

DHW

DHW

Heating water
return

Heating
water  flow

Heating
water  flow

Содержание CSW Series

Страница 1: ...Partno 3048457 Wolf GmbH D 84048 Mainburg Postfach 1380 Tel 49 8751 74 0 Fax 49 8751 741600 Installation instructions CSW TSW DHW cylinder connectionsetforinstallationonfinishedwalls 11 05 GB ...

Страница 2: ...tic hot water cylinder Domestic hot water Cold water DHW flow DHW return Primary return Primary flow Gas fired boiler Three way changeover valve Install the gas fired boiler in accordance with installation instructions Locate the DHW cylinder below and in alignment with the boiler DHW return vent valve DHW flow vent valve Gas fired boiler and DHW cylinder pipework TSW without decorative panel DHW ...

Страница 3: ...am to the control panel The pipes must provide a female thread at their ends and reach the connection panel Left hand supply lines Right hand supply lines Please note On site lines must be routed so that the CSW 120 TSW 120 DHW cylinders can be located flush against the wall Wind hemp around one side of the straight connector compression fitting and secure to the on site lines on the connection pa...

Страница 4: ... to size and insert the support sleeves into the pipe Wend hemp around one side of the elbow connector fitting an secure it on the saftey valve Insert the evacuation pipe into the elbow connector and tighten with the compression fitting Trim the DHW cylinder flow pipe from the connection set and locate on the cylinder side with union nut and locking ring Insert the support sleeve into the pipe Sec...

Отзывы: