Gas fired boiler and
DHW cylinder positioning

Three-way changeover
valve installation

Dummy plug
Primary
return

Elbow
Primary
flow

Gas fired boiler and DHW cylinder are installed in the following steps as shown:

- Remove the dummy plug from the heating return.

- Remove the bend from the heating flow.

- Install the three-way changeover valve from the connection set with the enclosed

gaskets to the heating flow.

CSW / TSW connection set
for installation on finished walls

Three-way
changeover
valve

Gas supply pipe

Domestic hot
water cylinder

Domestic hot water

Cold water

DHW flow

DHW return

Primary return

Primary flow

Gas fired boiler

Three-way
changeover valve

Install the gas fired boiler in accordance with installation instructions.

Locate the DHW cylinder below and in alignment with the boiler.

DHW return
vent valve

DHW flow
vent valve

Gas fired boiler and
DHW cylinder pipework

TSW without decorative panel

DHW cylinder cutout for supply lines

Connection
panel

780-

800

30

0

480

344

400

183

5 ±

 1

0

Connection
panel

DHW cylinder cutout for supply lines

TSW with decorative panel

27

0-42

0

79

0

810

1800

-19

50

CSW

Connection
panel

Connection
panel

DHW cylinder cutout for supply lines

Connection set ...SW-120 for
surface installation

Evacuation

P+T-Valve

P+T-pipe

Tundish

Содержание CSW Series

Страница 1: ...Partno 3048457 Wolf GmbH D 84048 Mainburg Postfach 1380 Tel 49 8751 74 0 Fax 49 8751 741600 Installation instructions CSW TSW DHW cylinder connectionsetforinstallationonfinishedwalls 11 05 GB ...

Страница 2: ...tic hot water cylinder Domestic hot water Cold water DHW flow DHW return Primary return Primary flow Gas fired boiler Three way changeover valve Install the gas fired boiler in accordance with installation instructions Locate the DHW cylinder below and in alignment with the boiler DHW return vent valve DHW flow vent valve Gas fired boiler and DHW cylinder pipework TSW without decorative panel DHW ...

Страница 3: ...am to the control panel The pipes must provide a female thread at their ends and reach the connection panel Left hand supply lines Right hand supply lines Please note On site lines must be routed so that the CSW 120 TSW 120 DHW cylinders can be located flush against the wall Wind hemp around one side of the straight connector compression fitting and secure to the on site lines on the connection pa...

Страница 4: ... to size and insert the support sleeves into the pipe Wend hemp around one side of the elbow connector fitting an secure it on the saftey valve Insert the evacuation pipe into the elbow connector and tighten with the compression fitting Trim the DHW cylinder flow pipe from the connection set and locate on the cylinder side with union nut and locking ring Insert the support sleeve into the pipe Sec...

Отзывы: