background image

4

Fit the gas connection, primary flow, primary return,P+T-pipe and tundish, DHW and
cold water pipes in that order to ensure a trouble-free installation.
Installation P+T-pipe and tundish and cold water supply according to manual DHW
cylinder CSW 120.

- Trim the gas pipe from the connection set to size.

Fit the union nut and compression rings, and insert the support sleeves into the gas
pipe.
Insert the gas pipe into the gas ball valve elbow and into the straight connector on
the connection panel, and tighten with the compression fittings.

- Trim the primary flow and return pipes from the connection set to size.

Fit the union nut and compression rings, and insert the support sleeves into the
primary flow and return pipes.
Insert the pipe into the straight valve (maintenance) elbow and into the straight
connector on the connection panel, and tighten with the compression fittings.

- Trim the DHW pipe from the connection set to size and insert the support sleeves into

the pipe.
Insert the DHW pipe into the straight connector on the DHW cylinder and into the
straight connector on the connection panel, and tighten with the compression fittings.

Please note: Shut-off equipment, dirt traps or other restrictions must not be

installed between the DHW cylinder and the safety valve.

- Trim the evacuation pipe to size and insert the support sleeves into the pipe.

Wend hemp around one side of the elbow connector fitting an secure it on the saftey
valve.
Insert the evacuation pipe into the elbow connector and tighten with the compression
fitting.

- Trim the DHW cylinder flow pipe from the connection set and locate on the cylinder

side with union nut and locking ring.
Insert the support sleeve into the pipe.
Secure the DHW cylinder flow pipe with compression fitting and with flat gasket on
the three-way changeover valve.

- Trim the DHW cylinder return pipe from the connection set and locate on the cylinder

side with union nut and locking ring.
Insert the support sleeve into the pipe.
Secure the DHW cylinder return pipe with compression fitting and with flat gasket on
the gas fired boiler.

Fill the heating system and vent carefully. During the filling process, vent the boiler at
air-vent valves in the boiler DHW cylinder flow and return.
Fill the DHW cylinder.
Switch ON the boiler and select the required DHW temperature at the boiler control unit:

Setting 1:

15 °C

Setting 7:

60 °C

Setting 9:          70 °C approx.

To raise the DHW temperature for a short time above 60 °C, pull the rotary temperature
selector for DHW approx. 3 mm out and turn clockwise.

Pipework installation

Initial start-up

DHW cylinder flow/return installation

DHW
return

DHW
flow

CSW / TSW connection set
for installation on finished walls

DHW return
vent valve

DHW flow
vent valve

Cold water

P+T- pipe

Primary
flow

Primary
return

Gas
pipe

Evacuation

Содержание CSW Series

Страница 1: ...Partno 3048457 Wolf GmbH D 84048 Mainburg Postfach 1380 Tel 49 8751 74 0 Fax 49 8751 741600 Installation instructions CSW TSW DHW cylinder connectionsetforinstallationonfinishedwalls 11 05 GB ...

Страница 2: ...tic hot water cylinder Domestic hot water Cold water DHW flow DHW return Primary return Primary flow Gas fired boiler Three way changeover valve Install the gas fired boiler in accordance with installation instructions Locate the DHW cylinder below and in alignment with the boiler DHW return vent valve DHW flow vent valve Gas fired boiler and DHW cylinder pipework TSW without decorative panel DHW ...

Страница 3: ...am to the control panel The pipes must provide a female thread at their ends and reach the connection panel Left hand supply lines Right hand supply lines Please note On site lines must be routed so that the CSW 120 TSW 120 DHW cylinders can be located flush against the wall Wind hemp around one side of the straight connector compression fitting and secure to the on site lines on the connection pa...

Страница 4: ... to size and insert the support sleeves into the pipe Wend hemp around one side of the elbow connector fitting an secure it on the saftey valve Insert the evacuation pipe into the elbow connector and tighten with the compression fitting Trim the DHW cylinder flow pipe from the connection set and locate on the cylinder side with union nut and locking ring Insert the support sleeve into the pipe Sec...

Отзывы: