3064202_201602
25
Default settings overview
16.2.2 Setting winter/summer changeover
Setting range: 0 °C to 40 °C
Factory setting: 20 °C
The
winter/summer changeover
function is only enabled if an outside sensor is
connected.
The winter/summer changeover function optimises the times when the system
operates in heating mode. If the average outside temperature is above the set winter/
summer temperature, the heating system switches to standby mode.
If the average outside temperature is below the set winter/summer temperature, the
heating system switches to automatic timer mode.
The period used to calculate the average outside temperature is set via the
A04 system parameter.
16.2.3 Setting ECO ABS
Setting range: -10 °C to 40 °C
Factory setting: 10 °C
The
ECO ABS
function is only enabled if an outside sensor is connected.
If the average outside temperature is above the ECO ABS temperature when in
economy mode, the heating/mixer circuit switches to standby mode.
If the average outside temperature is below the ECO ABS temperature, the control
unit switches back to economy mode.
You should only change the ECO ABS setting after consulting your contractor.
16.2.4 Setting day temperature (room temperature)
Setting range: 5 °C to 30 °C
Factory setting: 20 °C
Day temperature is only enabled for this heating/mixer circuit when the room
influence is enabled and the BM-2 is installed in the wall mounting base.
Use the day temperature to set the required room temperature in heating mode,
party function mode and the heating phases during automatic mode. In setback
mode, economy mode and during the setback phase in automatic mode, the room
temperature is only set to the day temperature less the economy factor (see point
18.3.1).
16.2.5
Setting room influence
Setting range: ON / OFF
Factory setting: OFF
Room influence
is only active if the BM-2 programming unit is installed as a remote
control.
Room influence can be used to compensate for fluctuations in room temperature
due to external sources of heat and cold (e.g. insolation, woodburning stoves or
open windows).
ON
= Room influence enabled
OFF
= Room influence disabled
Содержание BM-2
Страница 43: ...3064202_201602 43 Documentation information ...