3064202_201602
11
Simplified mode
Six operating modes are available:
Automatic timer mode:
Heating mode in programmed times
DHW heating in programmed times
DHW circulation pump in programmed times
Summer mode:
Heating system not in operation
DHW heating in programmed times
Frost protection active
Anti-seizing function active
Continuous operation:
Heating mode 24 hours
DHW heating in programmed times
DHW circulation pump in programmed times
Setback mode:
Heating mode with low temperature
DHW heating in programmed times
DHW circulation pump in programmed times
Standby mode:
Heating system not in operation
DHW heating not in operation
Frost protection active
Anti-seizing function active
Press the emissions test key to access emissions test mode
Emissions test mode is only necessary for the flue gas test.
Notes:
Simplified mode cannot be selected if a CWL or an ISM7/8 is connected to the WRS.
To exit simplified mode, press the rotary selector with pushbutton function (main menu). Turn and press to select
the default settings, call up the user interface and select "extended mode".
For extended mode (EM), see chapter "Overview of status pages".
In simplified mode, some setting options are not available
- Party function (temporary heating mode)
- Setback mode (date and time-controlled setback mode)
Содержание BM-2
Страница 43: ...3064202_201602 43 Documentation information ...