24
3064202_201602
Default settings overview
16.2 Heating circuit / mixer circuits 1-7
14:12
20.01.13
Heating appliance
Heating circuit
Mixer 1
Language
English
Default settings
14:12
20.01.13
Main menu
Display
Default settings
Time programs
Contractor level
Entry
The following is a list of all default settings for the heating circuit and mixer
circuits 1-7:
−
Economy factor in economy mode
−
Winter / summer changeover
−
ECO ABS
−
Day temperature (BM-2 in wall mounting base and room influence
enabled)
−
Room influence (BM-2 in wall mounting base)
16.2.1 Setting economy factor in economy mode
Setting range: 0...10
Factory setting: 4
For a detailed description see the "Heating curve / Economy mode" chapter
The economy factor describes by how much the heating curve sets back the heating
circuit or the mixer circuit when in economy mode. This factor has the same effect
as the -4...+4 setting, but is only used in the time program during the setback phase
or in setback mode.
Example of economy factor setting
(setting procedure is always the same).
14:12
20.01.13
Economy factor
5
Room influence
OFF
Winter / summer
Changeover
20 °C
ECO ABS
20 °C
Default settings
14:12
20.01.13
Economy factor
Setting range: 0 - 10
Factory setting: 2
Value:
4
Default settings
14:12
20.01.13
Time
12:25
Date
18.12.2014
Heating circuit settings
Mixer circuit settings
Default settings
14:12
20.01.13
Main menu
Display
Default settings
Time programs
Contractor level
Entry
Содержание BM-2