background image

 

11

 

„

 

Delete Phone Number 

In setup state, input [

51

] ~ [

56

], and then press [

#

] to confirm the main 

unit will make a long beep and the [

Signal

] indicator will flicker once and 

you will hear “delete completed”, which indicate the alarming user 
number is deleted successfully.

 

Operating method: [

XX

Ö

 [

#

XX 

indicates

:

 the 1- 6 alarming user number [

51

] ~ [

56

For example: Delete the third alarming user number from the system. 
Operating method: [

53

Ö

 [

#

LCD display: 

 

 

„

 

SMS Receiving Number Setting 

SMS Receiving number means when system is alarming, it will only 
send SMS to this mobile number. You can set maximum 3 SMS numbers. 
In setup state, input [

57

] ~ [

59

], then input the SMS receiving number, 

and then press [

#

] button to confirm. The main unit will make a beep, the 

[

Signal

] indicator will flicker once and you will hear “setting completed”, 

which indicate setup successfully. 

Operating method: [

XX

Ö

 [

YY…YY

Ö

 [

#

XX

 indicates: address codes of message-receiving numbers from the first 

group to the third group [

57

] ~ [

59

YY…YY 

indicates: the SMS receiving number 

For example: setup 13822222222 as the first SMS receiving number 
Operating method: [

57

Ö

 [

138222222

Ö

 [

#

 

„

 

Delete SMS Receiving Number 

In setup state, use keypad to input [

57

] ~ [

59

], and then press [

#

] button 

to confirm. The main unit will make a beep, the [

Signal

] indicator will 

flicker once and you will hear “delete completed”, which indicate SMS 
number is deleted successfully. 

Operating method: [

XX

Ö

 [

#

XX

 indicates: address codes of message-receiving numbers from the first 

 

12

group to the third group [

57

] ~ [

59

For example: delete the first SMS user number from the system 

Operating method: [

57

Ö

 [

#

 

„

 

Defense Zone Programming 

If you want to change the alarm attribute of defense zone, such as turn off 
the siren when system alarms, you can do it by defense zone 
programming. In setup state, first input [

60

], then the defense zone 

number [

01~99

], then input defense zone type [

1~4

], then input defense 

zone location number [

1~8

], and then select siren on/off [

0/1

], at last 

press [

#

] to confirm. You will hear the main unit emit a long beep and a 

voice prompt “setting completed”. 

Operating method: [

60

Ö

[

AA

Ö

[

B

Ö

[

C

Ö

[

D

Ö

[

#

AA: 

defense zone number

     

[

01~99

] means zone 1 to zone 99;

 

B: 

defense zone type

 

[

1

]: real-time defense zone      [

2

]: 40 seconds delay defense zone 

[

3

]: 24 hours defense zone      [

4

]: bypass defense zone 

    C: 

defense zone location 

[

1

] SOS Alarm              [

2

] Fire Alarm                [

3

] Gas Leak Alarm   

[

4

] Door Alarm              [

5

] Hall Alarm                [

6

] Window Alarm   

[

7

] Balcony Alarm        [

8

] Boundary Alarm 

D: 

siren ON/OFF: [

0

] OFF, [

1

] ON 

For example: set defense zone 12 to be 24-hour, fire alarm and siren on 
Operating method: [

60

Ö

[

12

Ö

[

3

Ö

[

2

Ö

[

1

Ö

[

#

 

„

 

Home Arm Defense Zone Setting 

If you want some detectors work and some do not, you can use [

Home 

Arm

] function. 

In setup state, use keypad to input [

61

], then choose the corresponding 

defense zone number [

01~99

], then choose [

Home Arm

], and then 

choose whether alarm [

0/1

] button, and finally press [

#

] to confirm. The 

main unit will make a long beep and a voice prompt “setting completed”. 

Operating method: [

61

Ö

 [

XX

Ö

 [

A

Ö

 [

#

XX indicates:

 [

01~99

] is defense zone 1 to defense zone 99 

Содержание YL-007M2B

Страница 1: ...s 12 Factory Reset 5 System Status 13 Coding of Remote Controller 5 Remote Controller Operate 13 Delete Remote Controller 6 Out Arm 13 Coding of Defense Zone 6 Home Arm 13 Delete Defense Zone 6 Disarm 14 Change Password 7 Answer Alarm Call 14 Change Operation Password 7 Remote Control 14 Change Program Password 8 Emergency Help 15 Clock Setting 8 System Dialing Function 15 Timing Settings 8 Alarmi...

Страница 2: ...y and boundary places alarm Real time delay 24 hours bypass defense zones programming function Wireless coding easy to add additional wireless accessories Remote control Arm Disarm Monitor and Intercom by phone Built in AAA NI HI rechargeable battery make alarm when power off Comply with CCC safety standard and GB12663 2001 national standard Alarm Host Diagram In order to make the main unit get th...

Страница 3: ...ss can delete the numbers input The system default password is 8888 Operating method XXXX Ö 6 X indicates the new 4 digit password LCD display Exit Settings Press and buttons the main unit emits a long beep and exits settings The SET indicator goes out and the system returns to disarm state Operating method Ǐ ǐÖǏ ǐ Factory Reset In disarm status use keypad to input 95175308246 and press to confirm...

Страница 4: ...want to delete 01 99 and then input to confirm The main unit emits a long beep and the defense zone indicator flickers once You will hear a voice prompt delete completed Operating method 24 Ö XX Ö XX indicates 01 99 defense zones number 8 Change Password 1 Change Operation Password Operation password is the password used to disarm or remote control In setup status use keypad to input 30 then input...

Страница 5: ... the hour AA and minute BB of the time you want to set to disarm and finally input to confirm You will hear a long beep and a voice prompt setting completed 10 Operating method XX Ö AA Ö BB Ö XX indicates the address code 36 37 38 of the timely disarming AA indicates the hour of the setting time BB indicates the minute of the setting time For example set the arm time as 55 7pm Operating method 33 ...

Страница 6: ...cates address codes of message receiving numbers from the first 12 group to the third group 57 59 For example delete the first SMS user number from the system Operating method 57 Ö Defense Zone Programming If you want to change the alarm attribute of defense zone such as turn off the siren when system alarms you can do it by defense zone programming In setup state first input 60 then the defense z...

Страница 7: ...ome 14 Arm will alarm when detectors are triggered z Disarm defense zone 1 99 will not alarm when detector triggered except 24 hours defense zone z System setup status In this status all defense zones will not alarm when detectors are triggered Remote Controller Operation Users can use remote controller to set system as Out Arm Home Arm Emergency Alarm Real time Disarm and etc z Out Arm Press butt...

Страница 8: ...led by the mobile until 16 30 seconds later Remote Control Dial the number associated to the alarm main unit by phone mobile phone and after one ringing cycle you can hear a voice prompt Please enter password If the password is right you will here Press 1 to arm Press 2 to disarm Press 3 to Monitor Press 4 to Intercom If the password is wrong you will hear a prompt voice wrong password please re e...

Страница 9: ... once a month if not permitted by condition you should check it at least every three months Check the main unit 1 Whether it can arm disarm normally 18 2 Whether it can dial the number for alarm normally 3 Whether it can receive wireless detectors signal normally 4 Whether the back up battery can work normally Check the wireless detectors 1 Trigger wireless detectors to see if system can alarm nor...

Страница 10: ...effective effective 24 hours Gas alarm yes Emergency button effective effective 24 hours Emergency alarm no Zone 7 99 effective invalid real time Emergency alarm yes Wired defense zone 96 99 effective invalid real time Emergency alarm yes Operation Password 8888 Remote control On Remote control Password 1234 Siren Off Siren sound time 180 sec Home Appliance Optional 20 Components list Main panel 1...

Страница 11: ... packed separately They include remote controller outdoor siren transmitter wireless PIR wireless gap sensor wireless gas detector wireless smoke detector panic button baluster etc You can choose according to your specific requirements ...

Отзывы: