Wolf-Guard YL-007M2B Скачать руководство пользователя страница 7

 

13

A indicates: [0] 

Home arm but not alarm

 

[1] 

Home arm and alarm 

For example: set defense zone 11 to be Home arm and alarm 
Operating method: [

61

Ö

[

11

Ö

[

1

Ö

[

#

For example: set defense zone 12 as Home arm but not alarm 
Operating method: [

61

Ö

 [

12

Ö

 [

0

Ö

 [

#

„

 

Artificial Recording 

In setup state, use keypad to input [

701

], and then press [

#

] to confirm. 

The main unit will emit a beep and the [

       

] indicator is on, and after 

10 seconds countdown, recording starts: record at 30cm away from the 
main unit with moderate tone; 10 seconds later, the main unit will make a 
beep indicating the recording stops and the recorded voice will replay. 

Operating method: [

701

Ö

 [

#

        LCD display:   

 

 

„

 

Siren Setting 

In setup state, use keypad to input [

75

]; in the operation of arm/ disarm by 

remote control, select if the siren sounds or not by [

0/1

] button, and then 

press [

#

] to confirm. The main unit will emit a long beep and a voice 

prompt “setting completed”. 

Operating method: [

75

Ö

 [

A

Ö

 [

#

]

 

indicates:

 

[

0

]

 

Siren off; [

1

] Siren on; System default: [

0

] Siren off

 

For example: set siren on when arm/ disarm 
Operating method: [

75

Ö

 [

1

Ö

 [

#

LCD display:   
 

 

 

Operation Instructions 

„

 

System status.There are 4 status as following: 

z

 

Arm:

 

defense zone 1~99 will alarm when detectors are triggered 

z

 

Home Arm:

 

in arm status, the defense zone which is set as [Home 

 

14

Arm] will alarm when detectors are triggered.

 

z

 

Disarm:

 

defense zone 1~99 will not alarm when detector triggered 

(except 24 hours defense zone)

 

z

 

System setup status: In this status, all defense zones will not alarm 
when detectors are triggered. 

 

„

 

Remote Controller Operation 

Users can use remote controller to set system as Out Arm, Home Arm, 
Emergency Alarm, Real-time Disarm and etc. 

z

 

Out Arm: Press    button 

z

 

Disarm: Press     button 

z

 

Home Arm: Press    button 

z

 

Emergency Alarm: Press        button, system will alarm at once.

 

„

 

Out Arm 

It means to guard all around your house while everyone is going out; all 
the detectors of the host are always working; when the detector is 
triggered by detecting source (anti-theft, fire prevention, gas leak, etc.), 
the alarm system will sound the alarm. 
Press [

Out Home

  ] button on keypad, system will make a beep per 

second and totally 100 beeps. The 

[OUT ARM] 

indicator will be on 

without flashing. It means Out Arm is set successfully. 

Arm Operation: Press [

Out Home

 ] button 

LCD display:   

 

 

„

 

Home Arm 

It means, for the safety, while somebody is at home, you need to enable 
the peripheral door, window, balcony and boundary detectors of the alarm 
system while prevent from triggering the indoor detectors, which may 
cause improper warning; then, you shall select Arm at Home, let just part 
of the detectors work and disable the other parts. 

Main Unit Operation: Press [

At Home

] button on keypad

 

Remote Control Operation: Press [

] button on remote controller. 

LCD display:   
 

Содержание YL-007M2B

Страница 1: ...s 12 Factory Reset 5 System Status 13 Coding of Remote Controller 5 Remote Controller Operate 13 Delete Remote Controller 6 Out Arm 13 Coding of Defense Zone 6 Home Arm 13 Delete Defense Zone 6 Disarm 14 Change Password 7 Answer Alarm Call 14 Change Operation Password 7 Remote Control 14 Change Program Password 8 Emergency Help 15 Clock Setting 8 System Dialing Function 15 Timing Settings 8 Alarmi...

Страница 2: ...y and boundary places alarm Real time delay 24 hours bypass defense zones programming function Wireless coding easy to add additional wireless accessories Remote control Arm Disarm Monitor and Intercom by phone Built in AAA NI HI rechargeable battery make alarm when power off Comply with CCC safety standard and GB12663 2001 national standard Alarm Host Diagram In order to make the main unit get th...

Страница 3: ...ss can delete the numbers input The system default password is 8888 Operating method XXXX Ö 6 X indicates the new 4 digit password LCD display Exit Settings Press and buttons the main unit emits a long beep and exits settings The SET indicator goes out and the system returns to disarm state Operating method Ǐ ǐÖǏ ǐ Factory Reset In disarm status use keypad to input 95175308246 and press to confirm...

Страница 4: ...want to delete 01 99 and then input to confirm The main unit emits a long beep and the defense zone indicator flickers once You will hear a voice prompt delete completed Operating method 24 Ö XX Ö XX indicates 01 99 defense zones number 8 Change Password 1 Change Operation Password Operation password is the password used to disarm or remote control In setup status use keypad to input 30 then input...

Страница 5: ... the hour AA and minute BB of the time you want to set to disarm and finally input to confirm You will hear a long beep and a voice prompt setting completed 10 Operating method XX Ö AA Ö BB Ö XX indicates the address code 36 37 38 of the timely disarming AA indicates the hour of the setting time BB indicates the minute of the setting time For example set the arm time as 55 7pm Operating method 33 ...

Страница 6: ...cates address codes of message receiving numbers from the first 12 group to the third group 57 59 For example delete the first SMS user number from the system Operating method 57 Ö Defense Zone Programming If you want to change the alarm attribute of defense zone such as turn off the siren when system alarms you can do it by defense zone programming In setup state first input 60 then the defense z...

Страница 7: ...ome 14 Arm will alarm when detectors are triggered z Disarm defense zone 1 99 will not alarm when detector triggered except 24 hours defense zone z System setup status In this status all defense zones will not alarm when detectors are triggered Remote Controller Operation Users can use remote controller to set system as Out Arm Home Arm Emergency Alarm Real time Disarm and etc z Out Arm Press butt...

Страница 8: ...led by the mobile until 16 30 seconds later Remote Control Dial the number associated to the alarm main unit by phone mobile phone and after one ringing cycle you can hear a voice prompt Please enter password If the password is right you will here Press 1 to arm Press 2 to disarm Press 3 to Monitor Press 4 to Intercom If the password is wrong you will hear a prompt voice wrong password please re e...

Страница 9: ... once a month if not permitted by condition you should check it at least every three months Check the main unit 1 Whether it can arm disarm normally 18 2 Whether it can dial the number for alarm normally 3 Whether it can receive wireless detectors signal normally 4 Whether the back up battery can work normally Check the wireless detectors 1 Trigger wireless detectors to see if system can alarm nor...

Страница 10: ...effective effective 24 hours Gas alarm yes Emergency button effective effective 24 hours Emergency alarm no Zone 7 99 effective invalid real time Emergency alarm yes Wired defense zone 96 99 effective invalid real time Emergency alarm yes Operation Password 8888 Remote control On Remote control Password 1234 Siren Off Siren sound time 180 sec Home Appliance Optional 20 Components list Main panel 1...

Страница 11: ... packed separately They include remote controller outdoor siren transmitter wireless PIR wireless gap sensor wireless gas detector wireless smoke detector panic button baluster etc You can choose according to your specific requirements ...

Отзывы: