background image

 

15

 
 
 

 

„

 

Disarm 

It means to stop the alarm when the main unit sounds the alarm or make 
the alarm system in the state of non-warning. After disarming, even if you 
trigger the detector, the main unit would not sound alarm (excluding 
24-hour defense areas). 
Use keypad to input system password, then press [

#

] button. [

Out Home

or [

At Home

] lights will be off. It means set system disarm successfully. 

Remote Control Operation: Press [

] button on remote controller 

Main Unit Operation: input system pa [

#

LCD display:   

 

 

„

 

Answer Alarm Call 

When the main unit sounds alarm, it will dial the preset numbers. If no 
one answers the call, the system will call the next user number 
automatically. The system will call each preset numbers for 3 times in 
order. 
If you answer the call, you will hear the pre-record voice. You can set 
system via your telephone or mobile phone keypad. 

If you hang-up directly without answering the call, the system will call 
each preset number for 3 times circularly.   

Press [*]

: Read the alarm information. 

Press [1]

: Main unit stops alarming and Arm; it stops calling users.

 

Press [2]

: Main unit stops alarming and Disarm; it stops calling users.

 

Press [3]

: Siren off and monitors the scene for 30 seconds; for continued 

monitoring, press [3] again to monitor for another 30 
seconds. 

Press [4]

: Main unit starts a 30-second two-way intercom. During this 

time, the main unit cannot be controlled by the mobile until 

 

16

30 seconds later. 

 

„

 

Remote Control 

Dial the number associated to the alarm main unit by phone (mobile 
phone), and after one ringing cycle, you can hear a voice prompt “Please 
enter password”. If the password is right, you will here “Press 1 to arm, 
Press 2 to disarm, Press 3 to Monitor, Press 4 to Intercom”. If the 
password is wrong, you will hear a prompt voice “wrong password, 
please re-enter”. 

Press [1]

: arm, if finished successfully, you will hear a voice prompt          

“System armed”. 

Press [2]

: disarm, if finished successfully, you will hear a voice prompt 

“System disarmed”.   

Press [3]

: monitoring for 30 seconds, to continue monitoring, press [3] 

again to monitor for another 30 seconds. 

Press [4]

: two-way intercom for 30 seconds. You can’t operate the main 

unit during this time. 

 

„

 

Emergency Help 

Press [Emergency

] button on keypad, or [

] button on remote 

controller or wireless panic button, the main unit will alarm and make call 
to the preset user numbers. 
 

„

 

System Dialing Function 

In disarm status; you can use the main unit to make any call just like a 
land-line telephone. Dial telephone number on keypad, press [

] button, 

the main unit will make a beep and the [

Signal

] indicator will be flashing. 

After the call, press [

] button again, the main unit will be in disarm 

status.

 

Alarming Record Checking 

In disarm state, input [*0#], then the main unit will make a long beep and 
enters the state of alarm record checking. After displaying the alarm and 
defense zone number indicator, the LCD screen will display the exact 
alarming time of this defense zone. Press 2, you can upturn to check the 

Содержание YL-007M2B

Страница 1: ...s 12 Factory Reset 5 System Status 13 Coding of Remote Controller 5 Remote Controller Operate 13 Delete Remote Controller 6 Out Arm 13 Coding of Defense Zone 6 Home Arm 13 Delete Defense Zone 6 Disarm 14 Change Password 7 Answer Alarm Call 14 Change Operation Password 7 Remote Control 14 Change Program Password 8 Emergency Help 15 Clock Setting 8 System Dialing Function 15 Timing Settings 8 Alarmi...

Страница 2: ...y and boundary places alarm Real time delay 24 hours bypass defense zones programming function Wireless coding easy to add additional wireless accessories Remote control Arm Disarm Monitor and Intercom by phone Built in AAA NI HI rechargeable battery make alarm when power off Comply with CCC safety standard and GB12663 2001 national standard Alarm Host Diagram In order to make the main unit get th...

Страница 3: ...ss can delete the numbers input The system default password is 8888 Operating method XXXX Ö 6 X indicates the new 4 digit password LCD display Exit Settings Press and buttons the main unit emits a long beep and exits settings The SET indicator goes out and the system returns to disarm state Operating method Ǐ ǐÖǏ ǐ Factory Reset In disarm status use keypad to input 95175308246 and press to confirm...

Страница 4: ...want to delete 01 99 and then input to confirm The main unit emits a long beep and the defense zone indicator flickers once You will hear a voice prompt delete completed Operating method 24 Ö XX Ö XX indicates 01 99 defense zones number 8 Change Password 1 Change Operation Password Operation password is the password used to disarm or remote control In setup status use keypad to input 30 then input...

Страница 5: ... the hour AA and minute BB of the time you want to set to disarm and finally input to confirm You will hear a long beep and a voice prompt setting completed 10 Operating method XX Ö AA Ö BB Ö XX indicates the address code 36 37 38 of the timely disarming AA indicates the hour of the setting time BB indicates the minute of the setting time For example set the arm time as 55 7pm Operating method 33 ...

Страница 6: ...cates address codes of message receiving numbers from the first 12 group to the third group 57 59 For example delete the first SMS user number from the system Operating method 57 Ö Defense Zone Programming If you want to change the alarm attribute of defense zone such as turn off the siren when system alarms you can do it by defense zone programming In setup state first input 60 then the defense z...

Страница 7: ...ome 14 Arm will alarm when detectors are triggered z Disarm defense zone 1 99 will not alarm when detector triggered except 24 hours defense zone z System setup status In this status all defense zones will not alarm when detectors are triggered Remote Controller Operation Users can use remote controller to set system as Out Arm Home Arm Emergency Alarm Real time Disarm and etc z Out Arm Press butt...

Страница 8: ...led by the mobile until 16 30 seconds later Remote Control Dial the number associated to the alarm main unit by phone mobile phone and after one ringing cycle you can hear a voice prompt Please enter password If the password is right you will here Press 1 to arm Press 2 to disarm Press 3 to Monitor Press 4 to Intercom If the password is wrong you will hear a prompt voice wrong password please re e...

Страница 9: ... once a month if not permitted by condition you should check it at least every three months Check the main unit 1 Whether it can arm disarm normally 18 2 Whether it can dial the number for alarm normally 3 Whether it can receive wireless detectors signal normally 4 Whether the back up battery can work normally Check the wireless detectors 1 Trigger wireless detectors to see if system can alarm nor...

Страница 10: ...effective effective 24 hours Gas alarm yes Emergency button effective effective 24 hours Emergency alarm no Zone 7 99 effective invalid real time Emergency alarm yes Wired defense zone 96 99 effective invalid real time Emergency alarm yes Operation Password 8888 Remote control On Remote control Password 1234 Siren Off Siren sound time 180 sec Home Appliance Optional 20 Components list Main panel 1...

Страница 11: ... packed separately They include remote controller outdoor siren transmitter wireless PIR wireless gap sensor wireless gas detector wireless smoke detector panic button baluster etc You can choose according to your specific requirements ...