Wolf-Guard YL-007M2B Скачать руководство пользователя страница 3

 

5

 

LCD display: 

 

Function Settings 

„

 

Initialization 

Please insert SIM card and plug in power adaptor, and then power on the 
system, all the LED lights will be on for 2 seconds and you will hear a 
long beep; the system comes into initialization. After the time clock 
displays on the LCD screen, the [

SGM

]

 

starts flashing and the main unit 

starts to detect the GSM network until a long beep. Then the [

SGM

indicator goes out indicating the system comes into disarm status. 

Finally, turn on the backup battery switch. 
 

„

 

Enter Settings 

In the state of disarm, input 4-digit password by the keypad on the main 
unit and press [

#

] button to confirm. You will hear a voice prompt: please 

enter instruction. At the same time, [

SET

] indicator is on without flashing 

and [0000] displays on the screen, indicating the system enters setting 
status. You can perform different settings repeatedly as long as the system 
keeps in setting status. The system will exit setting mode and return to 
disarm status if you don’t press any keypad button for 40 seconds.   

Note

˖

˖

In setting status

ˈ

press 

  can delete the numbers input

The system default password is [8888]

Operating method: [

XXXX

]

Ö

[

#

 

6

X

 indicates the new 4-digit password. 

 

LCD display: 
 

 

„

 

Exit Settings 

Press [

*

] and [

#

] buttons, the main unit emits a long beep and exits 

settings. The [

SET

] indicator goes out and the system returns to disarm 

state. 

Operating method: 

Ǐǐ

Ö

Ǐ

#

ǐ@

„

 

Factory Reset 

     

 

In disarm status, use keypad to input [

95175308246

] and press [

#

] to 

confirm, all the LED indicators will be on for 2 seconds and you will 
hear a long beep. The main unit gets all its settings cleared and restores 
to its factory settings successfully. 

Operating method: [

95175308246

] + [

#

 

„

 

Coding of Remote Controller 

The remote controller has to be code to the alarm host in order to 
perform normally.

 

In setup state, use keypad to input [

20

], input the remote controller 

number [

1~8

], and then press [

#

] to confirm. The main unit emits a long 

beep and you will hear “remote control coding”. The [        ] indicator is 
on without flashing; press any button on the wireless remote controller, 
the main unit makes a long beep and you will hear “coding completed”, 
[    ] indicator goes out, indicating the remote controller succeeds in 
coding. 
Operating method: [

20

Ö

 [

A

Ö

 [

#

         

A

 indicates

˖

1~8 remote controllers number. You can add maximum 8 

remote controllers. 

   

LCD display: 

 

Содержание YL-007M2B

Страница 1: ...s 12 Factory Reset 5 System Status 13 Coding of Remote Controller 5 Remote Controller Operate 13 Delete Remote Controller 6 Out Arm 13 Coding of Defense Zone 6 Home Arm 13 Delete Defense Zone 6 Disarm 14 Change Password 7 Answer Alarm Call 14 Change Operation Password 7 Remote Control 14 Change Program Password 8 Emergency Help 15 Clock Setting 8 System Dialing Function 15 Timing Settings 8 Alarmi...

Страница 2: ...y and boundary places alarm Real time delay 24 hours bypass defense zones programming function Wireless coding easy to add additional wireless accessories Remote control Arm Disarm Monitor and Intercom by phone Built in AAA NI HI rechargeable battery make alarm when power off Comply with CCC safety standard and GB12663 2001 national standard Alarm Host Diagram In order to make the main unit get th...

Страница 3: ...ss can delete the numbers input The system default password is 8888 Operating method XXXX Ö 6 X indicates the new 4 digit password LCD display Exit Settings Press and buttons the main unit emits a long beep and exits settings The SET indicator goes out and the system returns to disarm state Operating method Ǐ ǐÖǏ ǐ Factory Reset In disarm status use keypad to input 95175308246 and press to confirm...

Страница 4: ...want to delete 01 99 and then input to confirm The main unit emits a long beep and the defense zone indicator flickers once You will hear a voice prompt delete completed Operating method 24 Ö XX Ö XX indicates 01 99 defense zones number 8 Change Password 1 Change Operation Password Operation password is the password used to disarm or remote control In setup status use keypad to input 30 then input...

Страница 5: ... the hour AA and minute BB of the time you want to set to disarm and finally input to confirm You will hear a long beep and a voice prompt setting completed 10 Operating method XX Ö AA Ö BB Ö XX indicates the address code 36 37 38 of the timely disarming AA indicates the hour of the setting time BB indicates the minute of the setting time For example set the arm time as 55 7pm Operating method 33 ...

Страница 6: ...cates address codes of message receiving numbers from the first 12 group to the third group 57 59 For example delete the first SMS user number from the system Operating method 57 Ö Defense Zone Programming If you want to change the alarm attribute of defense zone such as turn off the siren when system alarms you can do it by defense zone programming In setup state first input 60 then the defense z...

Страница 7: ...ome 14 Arm will alarm when detectors are triggered z Disarm defense zone 1 99 will not alarm when detector triggered except 24 hours defense zone z System setup status In this status all defense zones will not alarm when detectors are triggered Remote Controller Operation Users can use remote controller to set system as Out Arm Home Arm Emergency Alarm Real time Disarm and etc z Out Arm Press butt...

Страница 8: ...led by the mobile until 16 30 seconds later Remote Control Dial the number associated to the alarm main unit by phone mobile phone and after one ringing cycle you can hear a voice prompt Please enter password If the password is right you will here Press 1 to arm Press 2 to disarm Press 3 to Monitor Press 4 to Intercom If the password is wrong you will hear a prompt voice wrong password please re e...

Страница 9: ... once a month if not permitted by condition you should check it at least every three months Check the main unit 1 Whether it can arm disarm normally 18 2 Whether it can dial the number for alarm normally 3 Whether it can receive wireless detectors signal normally 4 Whether the back up battery can work normally Check the wireless detectors 1 Trigger wireless detectors to see if system can alarm nor...

Страница 10: ...effective effective 24 hours Gas alarm yes Emergency button effective effective 24 hours Emergency alarm no Zone 7 99 effective invalid real time Emergency alarm yes Wired defense zone 96 99 effective invalid real time Emergency alarm yes Operation Password 8888 Remote control On Remote control Password 1234 Siren Off Siren sound time 180 sec Home Appliance Optional 20 Components list Main panel 1...