72
SDC-10
1080p D-IL A
®
3D Front Projector
User’s Manual
Command Format
The command between this unit and the computer consists of “Header”, “Unit ID”, “Command”, “Data” and “End”.
• Header (1 byte), Unit ID (2 bytes), Command (2 bytes), Data (n bytes), End (1 byte).
Header
This hexadecimal code indicates the start of communication.
Unit ID
This code specifies the unit. The hexadecimal code is fixed at “8901”.
Command and Data
Operating command and data (hexadecimal code)
Hexadecimal
Code
21
3F
40
06
Type
Operating command
Response command
Reference command
ACK
Description
PC
→
This unit
PC
→
This unit
This unit
→
PC
This unit
→
PC
(When the command is accepted without error, it returns to PC)
Command
0000
5057
4950
5243
Type
Connection check
Power supply
Input
Remote Control
Description
Check whether communication is available between this unit and
the PC during standby.
During standby
31: Turn on the power.
During power on
30: Turn off the power. (Standby mode)
During power on
32: COMP.
36: HDMI 1
37: HDMI 2
Sends the same code as the supplied remote control.
• “Remote control code” (Reference page: 72)