104
Examples:
(STD?L) What are the list options for the STD list control?
(STD!L001 001 00008 “Auto”)
(STD!L001 001 00007 “NTSC”)
(STD!L001 001 00003 “NTSC4.43”)
(STD!L001 001 00000 “PAL”)
(STD!L001 001 00004 “PAL‐M”)
(STD!L001 001 00005 “PAL‐C”)
(STD!L001 001 00006 “PAL‐60”)
(STD!L001 001 00002 “SECAM”)
(STD!L001 001 00009 “?”)
(STD!L111 “—END—”)
The end of the list is marked with P1=111. You can also access the text for a specific item in that list by adding the
value of that item after the L. For example:
(STD?L4) What is the text for item for in the Video Standard list?
(STD!L001 001 00004 “PAL‐M”)
CONTROL NAME:
To find out the name of the control you are using, add the letter “N” to your request message. If
the control uses indexes for multiple values, insert the index number after the “N” to read the name of the index.
For example:
(CON?N)
What is the name of the CON control?
(CON! “Contrast”)
(BRU?N2)
What is the name for index parameter 2 for BRU?
(BRU! “Left Side, R”)
(BRU?N6)
What is the name for index parameter 6 for BRU?
(BRU! “Top Left Corner, R”)
CONTROL TYPE:
To find out the type of control it is that you are using, add the letter “T” to your request message.
If indexes are being used for control with multiple values, insert the index parameter after the “T” to find out the
type of control that the index is. For some slide bar or number controls, an additional parameter may be returned
to specify the number of decimal places the control uses and if the control is to be displayed as a percentage
(0=min and 100=max). If the reply message does not contain the letter “T”, than this function is invalid for that
control.
Baud Rates
The baud rate setting determines the speed of communication to and from the projector on the RS232 or RS422
links. The maximum rate for the RS232 is 115200; for RS422 it is 19200. Set the baud rate to match that of your
controlling device, such as your PC. If you are unsure about what baud rate to choose, refer to the documentation
for the controlling device. In an existing network of projectors, if you discover that a projector has a different baud
rate, use the pull‐down list and select the correct baud rate using the ENTER key — do not just scroll this control
with the ARROW keys. Serial communication is always eight data bits, no parity.
Содержание REF-1000
Страница 1: ...1 REF 700 REF 1000 HOME THEATER PROJECTORS OWNER S MANUAL ...
Страница 27: ...27 FIGURE 3 1 REMOTE KEYPAD Wired Remote ...
Страница 94: ...94 Appendix B Menu Tree ...
Страница 95: ...95 ...
Страница 96: ...96 ...
Страница 100: ...100 Sampling Messages and Their Meaning ...
Страница 115: ...115 ...