Englisch
status 11.2020
7
4. Operating and indicating elements
1
Control plug
2
Main Button
3
Load plug
4
busbar adapter 30Compact
5
Display (only Connect Plus devices)
6
Arrow button (only Connect Plus devices)
5. Connection notes
WARNING: Danger to life by electric shock
Never carry out work when voltage is present.
5.1 Mains connection and line protection
•
When connecting the 3-phase network, it is essential to
observe the terminal identification.
•
The control supply voltage and control voltage inputs
must be operated with power supply modules according to
IEC 61131-2 (max. 5 % residual ripple).
•
In order to avoid inductive or capacitive coupling of noise
emissions where long control wires are used, we recom-
mend the use of shielded conductors.
6. Mounting (Image 2)
•
Snap the electronic motor starter onto the respective bus-
bar system 30Compact, 60Classic or directly onto the
CrossBoard
®
.
1
busbar adapter 30Compact
2
busbar adapter 60Classic
3
DIN rail adapter
4
Electronical motor starter
5
CrossBoard
®
7. Connection (Image 3)
The standard connection is realized using a 16-pin con-
nector. Connect the cables to the control plug of the motor
starter.
2
Clockwise
1
24 V / L+
4
Counterclockwise
3
GND / L-
6
24 V / L+
5
8
GND / L-
7
Enable -
10
Reset
9
Not connected
12
GND for inputs
11
C/Q line
14
98 (Error NO)
13
96 (Error NC)
16
12 (Warning NC)
15
95/11 (Common)
Enable-input
To put the motor connected to the device into operation,
you have to enable the device via the enable input.
As soon as a valid signal is present at the enable input (at
terminals EN + and EN-), the device accepts control com-
mands.
Image 1
Image 2
Image 3
Содержание 36255
Страница 1: ...Deutsch Stand 11 2020 1 MOTUS C14 ...
Страница 10: ...10 ...