Figure 2-15: Loudness Settings Screen
The controls and information available on the Loudness Meter Screen are:
Monitoring Mode
:
1.
Manual
: Touch the Manual button to enable Manual Mode. This allows you to
measure the loudness of a specific program or segment of a program, such
as a commercial. In this mode, the
Start
and
Stop
button on the Loudness
Meter screen can be manually used to begin and end a loudness
measurement interval. The reading for that interval is then held on the
Loudness Meter.
2.
Continuous
: Touch the
Continuous
button to enable Continuous Mode. In
this mode, loudness readings are continually made. The
Stop
button on the
Loudness Meter screen is not active.
Alarm
:
1.
Over
: The Alarm indication will only appear when Loudness has exceeded
the
Reference Level
by the
Tolerance
amount.
2.
Under
: The Alarm indication will only appear when Loudness is below the
Reference Level
by the
Tolerance
amount.
3.
Both
: The Alarm indication will only appear when Loudness has exceeded or
is below the
Reference Level
by the
Tolerance
amount.
4.
Off
: The Alarm indication will not appear.
Web GUI Loudness Settings
: These settings are included on this screen for
reference only. They cannot be changed on this screen.
1.
Standard
: This is the loudness standard by which the loudness calculation is
made.
2.
Reference
: This is the set point in the loudness measurement about which
the determination is made as to whether an alarm should be displayed.
3.
LRA Window
: This is a moving window of time over which the loudness
measurement is made.
4.
Window
: This may be set to
Momentary
,
Short
, or one of 22 values,
ranging from one second to two hours.
Note
: Further and more detailed descriptions of all of the above Loudness terms
Содержание iVAM1-12G
Страница 1: ...iVAM1 12G 1RU Multi Channel Audio Video 12G Monitor User Guide Part Number 821835 Revision C...
Страница 6: ...iVAM1 12G Page 6 Introduction 115 API Presets 115...
Страница 80: ...iVAM1 12G Page 80 Figure 4 21 Database Import...
Страница 101: ...iVAM1 12G Page 101 Figure B 6 Device View Network Config...