GMG-B Operation manual
Page 12 of 45
B0743
Filling connection
Cone lubricator nipple DIN 71412
Flat lubricator nipple DIN 3404
Closing nipple
Filling connection variants:
This part is located beneath the left-side pump element.
1)
not for oil suitably
3.5.4 Level monitoring (option)
The technical data of the (optional) level monitoring unit is as follows:
Switching voltage
max. 30 VDC
Switching current
max. 0,25 A
Switching power
max. 3 W
Temperature range
0
… +60 °C
Contact function
NC contact
When connecting inductive or capacitive loads, the relevant sup-
pressor circuits need to be provided for!
(Diode, RC element, varistor)
3.5.5 Control
The technical data of the (optional) control is as follows:
Control "C"
Power input
2 W
Input resistance
4,5 k
Ω
Temperature range
-
20 … +60 °C
Data buffer
10 years
Filling connector "G"
Closing nipple
Filling connector "W"
Closing nipple
Accessory for filling connector
"G" and "W":
Quick release
coupling
954.002-09
(p
max
= 35 bar)
Filling connector "A"
1)
Cone lubricator nipple
DIN 71412 - AG1/4
Filling connector "C"
1)
Flat lubricator nipple
DIN 3404 - M22