© wodtke GmbH - Tübingen.
IR_BA_190726
Page 15 / 64
ENGL
IS
H
Operation
•
Settings
3.1 Toughened safety glass plate
!
Material losses
Never operate the appliance when the toughened
safety glass is damaged.
The front of the appliance is made of 6 mm thick toughened
safety glass.
If damaged, the safety glass will shatter into many small pieces
with blunt edges to minimise any risk of injury. On very rare
occasions, safety glass can spontaneously break even without
external influences.
- Avoid any strain on the glass plate, e.g. caused by people
or objects leaning on it.
- When selecting an installation site, ensure that no persons
or objects can come to harm if the toughened safety glass
spontaneously breaks.
Note
Due to the manufacturing process for safety glass
(ESG), chemical and mechanical variations in the
surface quality are unavoidable. Minor flatness devi-
ations, round or linear inclusions, small bubbles and
roller wave distortion may occur and do not constitute
grounds for complaint.
4. Settings
CAUTION Burns
When pressing the ON/OFF switch, avoid any con-
tact with the potentially hot glass plate.
Note
Depending on the size and design of the appliance, it
may take some time for it to reach its operating tem-
perature.
Note
When the appliance is first commissioned, it may give
off an odour temporarily.
f
f
Ensure that the room is adequately ventilated
(with a partially open window, for example).
The ON/OFF switch is located on the outer edge of the appli-
ance.
D
00000
55
94
3
1
1 ON/OFF switch
f
f
Switch the appliance on or off using the ON/OFF switch.
The appliance is controlled exclusively via external room tem-
perature controllers.
f
f
Observe the operating and installation instructions of the
connected room thermostat.
5. Cleaning, care and maintenance
- After it has cooled down, clean the appliance with a damp
cloth and, if necessary, commercial glass cleaner.
- Never use any abrasive or corrosive cleaning products.
6. Troubleshooting
Problem
Cause
Remedy
The appliance
does not heat
up.
Fuse or safety switch
has blown/tripped.
Check the respective fuses and
safety switches.
Remove the cause.
Overheating. The high
limit safety cut-out has
tripped.
Remove the cause. The appli-
ance restarts after it has cooled
down for a few minutes.
If you cannot remedy the fault, contact your qualified con-
tractor. To facilitate and speed up your request, provide the