42
ROLL (D)
CV Controlled Roll. 1V = 1/4 Note, 2V = 1/8 Note,
3V = 1/16 Note, 4V = 1/32 Note
LOOP (D)
CV Controlled Loop. 1V = 8 Steps, 2V = 4 Steps,
3V = 2 Steps, 4V = 1 Step.
RESET (A)
Resets enabled tracks.
ERASE (D)
Erases steps at the playhead for enabled tracks
when the gate is high.
LOGIC OR (B)
Combines the gate at the ASSIGN input with the
pattern on enabled tracks.
LOGIC AND (D)
Enabled tracks will not play anything unless the
ASSIGN input is also high.
LOGIC INV (D)
When the gate is high, steps with data turn off. Steps
without data play as triggers.
RANDOM (C)
Generate a random pattern on selected tracks when
the gate goes high.
REC QUANTIZED (B)
Records any high gate on the ASSIGN input.
Quantized to 16th notes.
REC UNQUANTIZED (B)
Records any high gate on the ASSIGN input at 48ppqn
resolution.
NUDGE FORWARD(C)
Nudge all steps on enabled tracks to the right by one
when the gate transitions high.
NUDGE BACK (C)
Nudge all steps on enabled tracks to the left by one
when the gate transitions high.
NEXT VARIATION (C)
Trigger the next variation to play at the end of the
current variation.
PREVIOUS VARIATION
(C)
Trigger the previous variation to play at the end of
the current variation.
INSTANT NEXT
VARIATION (A)
Move to the next Variation immediately without
resetting playheads.
INSTANT RETURN TO
VAR A AND RESET (A)
Move to Variation A immediately and reset
playheads.
DISABLE
Assign type LED is off, input is ignored
Key:
(A) Rising edge immediate
(B) Real time polled
(C) Rising edge polled at clock
(D) Polled at clock
Assign Functions
9. ASSIGNABLE INPUTS
Содержание Metron
Страница 1: ...USER MANUAL ADVANCED TRIGGER AND GATE SEQUENCER METRON...
Страница 2: ...ADVANCED TRIGGER AND GATE SEQUENCER METRON...
Страница 10: ...9...
Страница 26: ...25...
Страница 34: ...Default Patterns 33 6 FILL FX P 8 P 7 P 6 P 5 1 32T 1 16T 1 8T 1 4T P 4 P 3 P 2 P 1 1 32 1 16 1 8 1 4...
Страница 40: ...39...
Страница 51: ......