Step #13: Ensure that the internal antenna UF.L connector (4) is connected to the mainboard. 
 
Step #14: Mount an LTE antenna to the external antenna connector on the device. 
 
Step #15: Install the modem enclosure (1) by the bottom-side and fasten / mount to wall – near 
to the meter – or

 mount to the wall of the water pit or the water pipe/pipeline in a fixed position 

by pipe clamps. 
 
Step #16: Install the external antenna magnetic mount to a metal part to fixate on the drain 
cover – to ensure open sky or undisturbed conditions for the antenna for the celular network 

signal reception. 
It is also necessary to have appropriate signal strength of the cellular network at the operating 

location/site.  You  can  change  the  position  of  the  antenna  on  the  location  for  a  better  signal 
coverage. 

 
Step #17: Put the enclosure’s top cover (2) and fasten the four screws (3). 
Then  the  internal  tamper  switch  (10)  will  be  pushed  and  the  device  will  be  turned  into 

configuration mode for 10 minutes – during this mode the LED signals will be active. Afterall the 
modem will be turned off and will be operating by its normal mode at the next wake-up cycle and 

will be sending data according to the presets (settings) you made on the modem. The LED will 
be inactive due to energy saving reasons. 

 
Step #18: When the APN and remote connection are already configured, the device will be able 
to connect to the NB-IoT network and send data. The connection and wireless transmission will 
be signed by its LED signal. 

 
Important!  When  the  configuration  was  unsuccesful  or  a  failure  came  up, then  remove  the 
enclosure’s top cover. Fix the issue and place the cover back to the modem’s enclosure. Therefore 
the modem will continue its operation sequence from the listed nr. 17. step. 
 

 

 

Содержание WM-I2

Страница 1: ...User manual for WM I2 metering modem v1 2 ______________________________________________ 2020 11 16...

Страница 2: ...the WM I2 pulse counter and transmitter device Document Version REV 1 2 Hardware Type Version WM I2 pulse counter modem Hardware Version V 2 10 Bootloader Version V 1 80 Firmware Version V 2 04 05 WM...

Страница 3: ...is in stand by operation Then it wakes up at the pre defined intervals to transmit the collected consumption data through the NB IoT mobile network to a server IP address Therefore the collected and c...

Страница 4: ...warning of a failure Battery capacity monitoring in case of low voltage detection it will notify about the necessity of battery exchange by transmitting the voltage level value Configuration The modem...

Страница 5: ...pter 2 Connections 2 1 External view 2 2 External view bottom side The top cover of the modem s enclosure which provides a safe and dehumified lock by using the internal silicone ring inside of the co...

Страница 6: ...e enclosure 4 Internal antenna connector U FL for SMA M connector 50 5 Special filled longlife battery Lithium Thyonyl Chloride 3 6V DC CR14250 type 6 SIM card slot for micro SIM 3FF type 7 Connection...

Страница 7: ...ut Connection interface with cabling terminal block J11 which can be used for connection the pulse input of the meter for connecting cables of cut detection Pin nr Comment 1 External battery not used...

Страница 8: ...ear a click sound Wiring of the configuration cable converter Step 4 For the serial configuration you need to use the USB UART converter adapter order option nr 11 with the provided 3 pin serial cable...

Страница 9: ...ed into position Step 6 The opposite side of the USB configuration cable must be connected to the J11 connector s terminal block nr 8 on the figure pins of WM I2 s mainboard nr 14 The wires must be pl...

Страница 10: ...nds Step 9 Download the WM I2 Term configuration software and configure the device by following the steps of the Chapter 3 Step 10 Connect the meter sensor wire to the J11 connector s terminal block n...

Страница 11: ...l coverage Step 17 Put the enclosure s top cover 2 and fasten the four screws 3 Then the internal tamper switch 10 will be pushed and the device will be turned into configuration mode for 10 minutes d...

Страница 12: ...rt transmitting period Thats why you need to run the configuration program on your PC and keep it open and connected to the device on its serial link until the next transmitting while the modem will g...

Страница 13: ...or the directory where you are using the program Step 4 Download the WM I2 TERM tool to your computer by using this link from a web browser https www m2mserver com m2m downloads WM I2Term_v0_4_4 zip S...

Страница 14: ...nto the popup window Step 4 Define a modem name logical identifier free to choose for the better device identification Use for onsite installation place unique name of identification etc Step 5 Then t...

Страница 15: ...one step device list must be in TXT extension text format You will find further icons to control the modem as SETTINGS you can configure the new device parameters for the modem or a define a new firm...

Страница 16: ...on settings cellular network settings selection of APN server port and IP address Extended configuration alarm settings life signal checking meter compatibility data sending schedule Templates and oth...

Страница 17: ...nfiguration Configuration port Cellular network country code network code choose the SIM provider from the list Step 2 Setup the minimum required fields on the Extended configuration tab and below at...

Страница 18: ...the minimum required fields on the Extended configuration tab and below at the Life signal and Time server settings tab Life signal sending IP address where you want to signalling the life signals of...

Страница 19: ...D when you connect the battery or pushing the tamper switch at enclosure top cover s close This is useful for testing the communication SIM and APN settings Note that the long operation time of the LE...

Страница 20: ...ta storage frequency define the data storage in memory cycle Step 6 At the Validity tab setup the following From Push the Today Now button and set the time manually increase by a few minutes To Push t...

Страница 21: ...or file to your computer If you want to send the configuration to the modem choose the Assign to IMEI button At the next connection in case of using the Connection settings Communication SETTINGS Send...

Страница 22: ...registered IP address Listener IP address and the Listener port number Serial port connection if you want to configura via serial local port Then choose the USB adapter modem COM port s number and 11...

Страница 23: ...guration will be ready to download by the GET button Then the configuration from the module will be downloaded into the WM I2 Term software here and the State will sign by the Sending data message At...

Страница 24: ...he log entries can be seen by pushing the icon and choosing the Event Log tab The list can be orderd and saved into various formats here by the buttons 3 9 Refresh modem firmware Step 1 Choose the ico...

Страница 25: ...Step 2 Chose the Firmware tab and the Choose Firmware button and browse the firmware file you want to upload to the modem with dwl extension...

Страница 26: ...already configured At the next connection Connection settings Connection SETTINGS Sending data the new firmware will be sended to the modem Push to the Assign to IMEI button to save the request for t...

Отзывы: