![Wiznet WIZ110SR Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/wiznet/wiz110sr/wiz110sr_user-manual_990655021.webp)
Copyright © WIZnet All Rights Reserved
WIZ110SR | 21 page
4. Serial Configuration
4.1.
Serial Command Format
It is possible to configure WIZ110SR by using serial command.
By inputting specified 3 characters you can enter into the configuration mode. The characters
can be defined at the Configuration Tool.
<Frame Format>
Command Frame format
Descriptor
STX
Command code
Parameter
ETX
Length(bytes)
1
2
Variable
1
Table 3. Serial Configuration Frame Format
Reply Frame format
Descriptor
STX
Reply code
Parameter
ETX
Length(bytes)
1
1
Variable
1
Table 4. Serial Configuration Reply Frame Format
STX & ETX
Setting
Comments
STX
„<‟ : Hex = 3Ch
ETX
„>‟ : Hex = 3Eh
Table 5. Serial Configuration STX & ETX
Reply Code
Reply
Comments
S
Command was successful
F
Command failed
0
Invalid STX
1
Invalid command
2
Invalid parameter
3
Invalid ETX
E
Enter serial command mode
Table 6. Serial Configuration Reply Code