Original operation manual
19
AirlessPhoenixGX_BA_en_1803 • 0550010-en • jw
Safety
2.4.2 Compressed air shut-off valve
The compressed air shut-off valve on the maintenance unit
interrupts the air supply to the entire machine. The machine
immediately stops and the compressed air is released.
The functional principle:
➤
To open / opened
Position
in the flow direction
Fig. 3: Compressed air shut-off
valve OPEN
➤
To close / closed
Position
transverse to the flow direction
Fig. 4: Compressed air shut-off
valve CLOSED
After shutting off the air, the machine remains under pressure
with regards to material. Perform a complete pressure relief
before all work on the machine (see chap. 5.5 ‘Relieving the
pressure’ on page 38!
2.4.3 Ground cable
The ground cable serves to
prevent electrostatic charging
of the machine.
The ground cable is already
connected to the machine at
the time of delivery (e.g. to
the high pressure filter, the
grounding rail, or the like).
Fig. 5
: Ground cable
If the ground cable is lost or defective, replace it immediately
(art. no. 0659675)!