Original operation manual
23
AirlessPhoenixGX_BA_en_1803 • 0550010-en • jw
Safety
2.7 How to respond in an emergency
2.7.1 Bring the machine to a standstill and relieve the pressure
In an emergency, bring the machine to an immediate standstill and
relieve the pressure.
1.
Close the compressed air shut-off valve.
2.
Actuate the spray gun briefly once more.
3.
Open the relief valve on the high pressure filter, so that no
further material pressure is present and the machine has been
fully relieved of pressure.
This process is not suitable for decommissioning. The machine is
not flushed.
➤
For controlled decommissioning, please see chap. 5.6 ‘Work
interruption’ on page 39
.
➤
After remedying the emergency situation, the machine must be
flushed (see chap. 5.3 ‘Flushing’ on page 36
)
. Observe the
pot life of the materials used.
2.7.2 Leakage
WARNING
In case of leakage, material may escape under very high pressure
and cause serious physical injuries and property damage.
➤
Bring the machine to an immediate standstill and relieve the
pressure.
➤
Tighten threaded connections and replace defective parts
(must be performed by trained personnel).
➤
Do not seal leakage at connections and on high pressure
hoses with the hand or by wrapping.
➤
Do not patch material hoses!
➤
Check hoses and threaded connections for leak-tightness
before starting the machine up again.
2.7.3 Injuries
In case of injuries caused by processing material or cleaning
agents, always have the safety data sheet ready to show the doctor
(supplier or manufacturer address, their telephone number, material
designation and material number).