Mechanical installation
j
| BA 14.0197 | 11/2010
30
Stop!
Before adjusting dimensions "s", check air gap "s
Lü
" and, if necessary, adjust to
"s
Lürated
" (
15) (
23). During air gap adjustment, the brake is
not
energised.
BFK464−XX−S−004a.iso/dms BFK464−XX−S−015.iso/dms
Fig. 13
Dimension "s
Lü
" and "s"
1.1 Stator
2
Armature plate
6
Flange
Type
s
Lürated
+0.05
[mm]
s
+0.1
[mm]
BFK464−
18S
0.4
5.3
BFK464−
19S
BFK464−
20S
BFK464−
20S.1
BFK464−
25S
BFK464−
28S
0.5
6.5
Danger!
Brake may fail
If the manual release is not adjusted correctly the brake may fail.
Possible consequences:
| Severe injuries or material damage.
Protective measure:
| Observe dimension "s".