Subject to change without notice!
EN
HYDRA PLUS UD300 CAR DOOR
Code
Version
Code
Version
Date
Page
GM.2.002668.EN
B
3201.32.0397
B
04.02.2013
36.37
WARNINGS ON HOW TO KEEP THE DOORS IN GOOD OPERATING CONDITIONS
In order to prevent failures or incorrect operation and to maintain the system in good conditions, the technical efficien-
cy of the system should periodically be checked, to ensure compliance with the applicable laws.
The technical efficiency depends on various factors such as:
- Work load
- Years of operation
- Door weight
- Climatic and environmental conditions
- Cleanness of environment
- Correct maintenance
- Etc.
And it can affect:
- Clearance/interference between the doors, and between the doors and posts according to the applicable laws
- Clearance of coupling device
- Status/conditions of fixing and coupling elements
- Conditions of parts affected by wear
- Efficiency of the lock and relevant contacts
- Any other parts that may be affected by the type of application.
For these reasons it is not possible to establish a general part replacement programme beforehand.
All screws used for the assembly of our product are screwed by means of a tightening torque as shown on following table:
Screw
Max torque (Nm)
Min torque (Nm)
M3
1,1
0,9
M4
2,6
2,1
M5
5,1
4,1
M6
9
7
M8
21
17
M10
42
34
M12
71,4
57,1
In case of need please refer to above table.