Subject to change without notice!
EN
HYDRA PLUS UD300 CAR DOOR
Code
Version
Code
Version
Date
Page
GM.2.002668.EN
B
3201.32.0397
B
04.02.2013
11.37
Fig. 1
Fig. 2
A
B
5. CLEARANCE RECOVERING OF THE PANEL ASSEMBLING BOLTS
When the panels are hung to the hanger tracks the fixing screws should be placed according to figure (1).
For standard opening doors (up to 850 mm) the distance between the screws “B” is small compared to the clear opening height (at least 2
metres high).
This means that the clearance “A” can be varied by means of adjusting panel hanger bolts, which permits up to 30 mm of adjustment.
This can be avoided by installing panels as figure (2) during erection.
The panel height adjustment must be made after having effected the clearance recovering.
Standard position for the fixing screws of panel
hanger bolts at the time of assembling.
Position to be assumed by the fixing screws of panel
hanger bolts; in order to get it, please push the panel in
the direction of the opening.