Programming of the codes
In all locks, the same codes must be programmed
for the according users, e.g.
User 08:
Code: Lock 1: 08080808
Code: Lock 2: 08080808
or
Code: Lock 3: 08080808
Notes:
1. For this functionality, the explicit four-eye code
(code linkage) is deactivated.
2. This function is only approved for 2 or 3 lock
operation.
Activate TwinXT
Lock I/O. The inputs and outputs of the extension
unit TwinXT are activated and queried.
Quick unlocking code
A user code that skips the unlocking delay can be
defined as quick unlocking code.
Factory setting in the lock: User 09
General
Forced sequence
programmable, i.e. the unlocking
and locking sequence.
Unlocking: Lock 01 -> Lock 02
Locking:
Lock 02 -> Lock 01
Battery warning limit:
With this function, the threshold of the battery
warning can be set between 6.8 V and 9.3 V.
Critical dropping of the supply voltage is
automatically detected and the following message
is displayed:
Switching to
Daylight savings time:
The time is automatically switched at the last
weekend in March and at the last weekend in
October.
Manual locking
can only take place via a code entry.
Code query
*** TwinLock ***
!!! Low Batt !!!