7.5. Programming Partial Blocking Times
Partial blocking time
Two time periods for each of the seven days of the week are available, during which
the system may be partially blocked.
The partial blocking is only designed for two lock operation.
Both locks are opened by entering a code.
Within the partial blocking time, only lock 2 is closed; lock 1 remains open.
The evaluation of the partial blocking time takes place during each locking procedure.
If lock 01 must be quickly locked despite an active partial locking time, the ENTER
key must be pressed during the locking procedure when “Locking lock 01” “Partially
locked!” is displayed. This will skip the partial locking time and close lock 01.
The partial locking time can be combined with the function „automatic locking“ via
door switch and will perform the locking after the configured total blocking time has
started.
Factory setting:
Mo … Su.: 00:00-00:00
Partial blocking time deactivated
00:00-00:00
Attention:
To ensure proper functioning of the weekly program, the correct
setting of the date, time and weekday is required.