Malfunction
Cause
Remedy
•
Incorrect mixture
•
Gas supply pipe mal-
function
•
The inlet pressure has
dropped below the min.
•
Clean filters in the inlet or
replace if necessary
(see Sec. 7.4)
•
Check inlet pressures
(see tech. data, Sec. 9)
•
Incorrect mixture
•
Incorrect setting of pro-
portion.
•
Solenoid valve leaks. A
very low flow is still
passing through the so-
lenoid valve, filling the
receiver up to control
pressure
•
Receiver pressure / max.
switching point setting to
high
•
Receiver pressure is
correctly set, but sole-
noid valve does not cut-
off the mixed gas flow at
max. receiver pressure
set-point
•
Incorrect pressure drop
between inlet-, control-,
max. receiver pressure
under flowing conditions
•
Alter setting due to require-
ment
•
Isolate mixed gas line down-
stream of the receiver and
observe receiver pressure
gauge. If receiver pressure
exceeds set max. value
(switching point) check cor-
rect setting of pressure switch
first
•
Solenoid valve faulty.
Contact
WITT-GASETECHNIK
•
See manual, alter setting of
pressure switch, according to
data indicated in manual. If
pressure switch does not al-
low correct setting, replace.
•
Solenoid valve faulty.
Contact
WITT-GASETECHNIK
•
Follow manual, alter pressure
settings, if necessary
•
Solenoid valve opens/
closes in very high frequen-
cy (less than 2-3 sec.)
•
Size of mixed gas re-
ceiver does not fit with
mixer capacity
•
Restrictions between
mixer and receiver or in-
correct pipe-diameter
•
Mixed gas consumption
is slightly beneath mixed
gas max. capacity
•
Observe recommendation of
manual, install receiver of
suitable size
•
Check pipe and pipe-
diameter and install tube with
sufficient diameter
•
Increase inlet pressure/ con-
trol pressure to achieve high-
er capacity
•
No lights on alarm
module
•
No power supply
•
Alarm module faulty
•
Check connection to the
mains or connect to the
mains
•
Contact
WITT-GASETECHNIK
Note!
In the case of other malfunctions contact us or an authorised centre to have the unit
checked.
The gas mixer is only permitted to be placed back in operation after it has been checked
and repaired by us or an authorised centre.