6 Pump description
Traditional pumps account for 10 to 20% of electricity consumption in an average household.
Together with the HE + go.future series of pumps, we have developed a circulation pump with
an energy efficiency index
≤
0.20. Thanks to the use of these pumps, energy consumption can
be reduced by up to approx. 80% compared to a traditional circulation pump. The hydraulic
power is kept at almost the same level as in the case of standard pumps. The pump power is
adjusted to the actual demand as it works according to the proportional pressure principle.
7
Pump settings and capacity
Description of the operating elements
7.1 Buttons
All pump functions can be controlled with just two buttons.
Lower „MODE” button can be used to change the level of work and the button
can be used to
switch on and off the night reduction mode.
7.1.1 Service mode, setting the capacity range
In service mode, the capacity range can be
changed to 4m, 5m and 6m.
• The pump must be disconnected from the
230V mains voltage for at least 15 seconds.
• Connect the pump to the 230V mains vol-
tage.
• Within 3 seconds press MODE
buttons
simultaneously.
• Then release both buttons.
• Select the capacity range with the
and buttons.
• 2 = 5m
• 1 = 4m
• 0 = 6m
• The pump must be disconnected from the
230V mains voltage for at least 15 seconds.
• Connect the pump to the 230V mains
voltage.
• Pressing the MODE button > 3 seconds
displays the set operating level.
T
T
T
29